3OM-1064-001.pdf - 第66页

Error Code Display A Display B 0005-002 2-24 Tg0248-PM-ER 3. T rouble Shooting after Error Display 04 01 04 YB-AXIS ORIGIN ENCODER ORIGIN W AS DETECTED A T POINT OUT OF ORIGIN (SLIDE). (Cause 1) Is the original position …

100%1 / 308
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
3. Trouble Shooting after Error Display
0005-002 2-23 Tg0248-PM-ER
03 06 01 XB-AXIS INTERLOCK
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
04 01 01 YB-AXIS ORIGIN ENCODER ORIGIN WAS NOT DETECTED.
(Cause 1) Motor encoder section may be defective.
(Cause 2) Encoder cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Turn off the power and check for loose connections between the sections of the motor and
signal cable.
(2) Re-start.
(3) If the device can’t be reset even after the above check, contact our service personnel because
the signal cable may be broken or the motor defective.
04 01 02 YB-AXIS ORIGIN ORIGIN (SLIDE) WAS NOT DETECTED.
;C(B)-BPH021 E/R
(Cause 1) The sensor may be defective.
(Cause 2) The cable may be broken.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [RESET] button to cancel the error.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel because a sensor or sensor
cable replacement might be required.
04 01 03 YB-AXIS ORIGIN ORIGIN SENSOR (SLIDE) AND/OR LIMIT SENSOR ()
MIGHT BE DEFECTIVE.
Error Code Display A Display B
0005-002 2-24 Tg0248-PM-ER
3. Trouble Shooting after Error Display
04 01 04 YB-AXIS ORIGIN ENCODER ORIGIN WAS DETECTED AT POINT OUT
OF ORIGIN (SLIDE).
(Cause 1) Is the original position deviated?
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Re-adjust the original position.
(2) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(3) Press the [ZERO] button to return all the axes to their original positions.
(4) Re-start.
(5) If the device can’t be re-started, contact our service personnel.
LIMIT SENSOR (+)/() MIGHT BE DEFECTIVE.
(Cause 1) It may run away due to noise or overcurrent.
(Cause 2) The sensor may be defective.
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
04 01 05 YB-AXIS ORIGIN ORIGIN IS NOT SET FOR THIS AXIS.
ZEROING IS REQUIRED.
04 01 06 YB-AXIS ORIGIN THE AXIS WAS NOT AT ORIGIN.
04 01 10 YB-AXIS ORIGIN ZEROING NOT COMPLETED WITHIN SPECIFIED
TIME.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
04 01 11 YB-AXIS ORIGIN
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
Error Code Display A Display B
0005-002 2-25 Tg0248-PM-ER
3. Trouble Shooting after Error Display
04 02 01 YB-AXIS TIMING PREVIOUS TASK WAS NOT COMPLETED.
UNABLE TO CONTINUE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
04 03 02 YB-AXIS DATA CORRECTION VALUE IS OUT OF FEEDER (B) OFF-
SET RANGE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
04 03 01 YB-AXIS DATA TARGET LOCATION VALUE IS OUT OF RANGE.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.