3OM-1064-001.pdf - 第291页

6. Nozzle Recognition Error Code and List of Error Messages Shown below are the contents of error codes which might be issued in the nozzle recognition processing. Detail Code ID Code of Recognition Function (30) Error I…

100%1 / 308
5. Component Recognition Error Code and List of Error Messages
0103-002 4-59-1 Tg0248-PM-ER
Error Code Display A Display B
20XXXXXX COMPONENT DETECTION
except the ERROR
above-
described
codes
ETC.
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [ZERO] button to return all the axes to their original positions.
(2) Re-start.
(3) If the device can’t be re-started, contact our service personnel.
THE LEADS LOCATED AT THE ENDS OF THE AR-
RAYED LEADS CANNNOT BE DETERMINED.
20672801 COMPONENT DETECTION
ERROR
WIDTH OF LEAD EXCEEDS THE TOLERANCE.
20672800 COMPONENT DETECTION
ERROR
LEAD POSITION (LEAD LENGTH DIRECTION) WAS
OUT OF TOLERANCE.
20672856 COMPONENT DETECTION
ERROR
THE DETECTED BALL POSITION DOES NOT MATCH
THE POSITION DATA.
20672855 COMPONENT DETECTION
ERROR
THE DETECTED BALL POSITION DOES NOT MATCH
THE POSITION DATA.
20672670 COMPONENT DETECTION
ERROR
SOME BALLS CANNOT BE DETECTED.
20672859 COMPONENT DETECTION
ERROR
BALL POSITION WAS OUT OF TOLERANCE.
20672858 COMPONENT DETECTION
ERROR
UNSPECIFIED BALLS ARE DETECTED.
20672881 COMPONENT DETECTION
ERROR
COMPONENT OUTWARD LENGTH Y WAS OUT OF
TOLERANCE.
20672880 COMPONENT DETECTION
ERROR
COMPONENT OUTWARD LENGTH X WAS OUT OF
TOLERANCE.
20672857 COMPONENT DETECTION
ERROR
6. Nozzle Recognition Error Code and List of Error
Messages
Shown below are the contents of error codes which might be issued in the
nozzle recognition processing.
Detail Code
ID Code of Recognition Function (30)
Error ID Code (00)
ccccss
0005-002 4-60 Tg0248-PM-ER
6. Nozzle Recognition Error Code and List of Error Messages
0009-003 4-61 Tg0248-PM-ER
6. Nozzle Recognition Error Code and List of Error Messages
Error Code Display A Display B
30000041 NOZZLE RECOGNITION
ERROR
NOZZLE WAS NOT DETECTED.
(Cause 1) Is there any error in the jig nozzle installation?
Is there any error in the jig nozzle adjustment?
(Cause 2) Does the nozzle type data exceed the set range?
(Reset Procedure in the case of Causes 1 and 2)
Reset Procedure
(1) Install the jig nozzle correctly.
(2) Adjust the jig nozzle to be used correctly.
(3) Set the nozzle type data correctly.
30000051 NOZZLE RECOGNITION
ERROR
“NOZZLE SIZE X” EXCEEDS THE RANGE OF SET-
TING.
30000052 NOZZLE RECOGNITION
ERROR
“NOZZLE SIZE Y” EXCEEDS THE RANGE OF SET-
TING.
30000061 NOZZLE RECOGNITION
ERROR
“NOZZLE POS. (X)” EXCEEDS THE RANGE OF SET-
TING.
30XXXXXX NOZZLE RECOGNITION
except the ERROR
above-
described
codes
ETC.
30000062 NOZZLE RECOGNITION
ERROR
“NOZZLE POS. (Y)” EXCEEDS THE RANGE OF SET-
TING.
30000071 NOZZLE RECOGNITION
ERROR
NOZZLE WAS NOT DETECTED.
30000053 NOZZLE RECOGNITION
ERROR
“NOZZLE OUTER SIZE X” WAS MORE THAN TOLER-
ANCE.
30000054 NOZZLE RECOGNITION
ERROR
“NOZZLE OUTER SIZE Y” WAS MORE THAN TOLER-
ANCE.
30000055 NOZZLE RECOGNITION
ERROR
“NOZZLE OUTER SIZE X” WAS LESS THAN TOLER-
ANCE.
30000056 NOZZLE RECOGNITION
ERROR
“NOZZLE OUTER SIZE Y” WAS LESS THAN TOLER-
ANCE.
30010000 NOZZLE RECOGNITION
ERROR
POLARITY DETERMINATION AREA IS OUT OF VISUAL FIELD FOR
RECOGNITION BECAUSE OF IMPROPER COMPONENT HANDLING.