3OM-1064-001.pdf - 第299页

10. Camera Gain & Level T eaching Error Code and List of Error Messages Shown below are the contents of error codes which might be issued in the camera gain & level teaching processing. 10. Camera Gain & Leve…

100%1 / 308
0005-002 4-67 Tg0248-PM-ER
9. Camera Magnification Teaching Error Code and List of Error Messages
Error Code Display A Display B
60000000 TEACH CAMERA MAGNIFICA-
TION ERROR
THERE IS A BIG DIFFERENCE X AND Y IN THE
RESULT OF MAGNIFICATION.
THE MEASURED MAGNIFICATION DOES NOT MEET
THE SPECIFICATIONS OF THE MACHINE.
60XXXXXX TEACH CAMERA MAGNIFICA-
except the TION ERROR
above-
described
codes
ETC.
60000001 TEACH CAMERA MAGNIFICA-
TION ERROR
CONTRAST BETWEEN DOT AND BACKGROUND IS
TOO LOW.
60676030 TEACH CAMERA MAGNIFICA-
TION ERROR
THE DOTS CANNOT BE DETECTED ADEQUATELY.
60676031 TEACH CAMERA MAGNIFICA-
TION ERROR
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.
10. Camera Gain & Level Teaching Error Code and
List of Error Messages
Shown below are the contents of error codes which might be issued in the
camera gain & level teaching processing.
10. Camera Gain & Level Teaching Error Code and List of Error Messages
0005-002 4-68 Tg0248-PM-ER
Detail Code
ID Code of Recognition Function (61)
Error ID Code (01)
ccccss
0005-002 4-69 Tg0248-PM-ER
10. Camera Gain & Level Teaching Error Code and List of Error Messages
Error Code Display A Display B
61010000 TEACH CAMERA GAIN/LEVEL
ERROR
THE TEACHING OPERATION DID NOT END WITHIN
THE SPECIFIED NUMBER OF TIME.
HEAD LIGHTING OFF.
61XXXXXX
TEACH CAMERA GAIN/LEVEL
except the ERROR
above-
described
codes
ETC.
61010001 TEACH CAMERA GAIN/LEVEL
ERROR
GAIN OR LEVEL EXCEEDS THE RANGE OF TUNING.61010002 TEACH CAMERA GAIN/LEVEL
ERROR
(Cause 1) This is the device’s self-diagnostic message.
(Reset Procedure in the case of Cause 1)
Reset Procedure
(1) Press the [CLEAR ALARM] key and the buzzer stops sounding.
(2) Press the [ZERO] button to return all the axes to their original positions.
(3) Re-start.
(4) If the device can’t be re-started, contact our service personnel.