DECAN_S1_Administrator′s_Guide(Eng_Ver1.5)_Print.pdf - 第389页
14-7 Machine Calibration 14.1.3. <R Axis> tab dialog Displays the R axis compensation value of each head, or determines whether to compensate the R axis. Data in this dialog box is updated automatically if the R-Ax…

14-6
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
default values.
Erased data cannot be restored. Fiducial Camera Offset Calibration and Head Offset
Calibration must be performed again to apply the fiducial camera offset and head
offset.

14-7
Machine Calibration
14.1.3. <R Axis> tab dialog
Displays the R axis compensation value of each head, or determines whether to
compensate the R axis. Data in this dialog box is updated automatically if the R-Axis
Offset Calibration is executed during camera calibration and the result value is reflected.
Setup whether to apply compensation on the R-axis of each head or not.
Figure14.3 “R AXIS” tab dialog
<Check Data> group
Indicates the R axis compensation value of each head.
<Device> combo box
Select the head.
<Use Compensation> check box
Determines whether to use the R axis compensation method for each head.
<Update> button
Transmits the change data to the equipment and closes the dialog box.
<Cancel> button
Ignores the change data and closes the dialog box.

14-8
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
14.1.4. <Fly-Fix Offset> tab dialog
Sets the Fly-Fix offset for each head. Data in this dialog box is updated automatically if the
Fly to Fix Offset Calibration is executed during camera calibration and the result value is
reflected.
Figure14.4 “Fly-Fix Offset” tab dialog
<Device> combo box
Sets the Fly-Fix offset for each head.
<Fly To Fix Offset>
<Degree> column
Sets the Fly-Fix offset by degree at 45 degree interval.
<X, Y> column
Sets the Fly-Fix offset of X, Y.
<Fly Run Out Offset>
<Degree> column
Fly-Fix offset for each angle can be setup at the interval of 45 degrees.
<X, Y> column
Sets the Fly Run Out offset of X, Y.
<Clear data for this Head> button
Deletes Fly-Fix offset data of the selected head. Used when not applying the Fly-Fix
offset on the head. Data cannot be restored once it has been deleted. To apply the Fly-