14-54 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide Caution Before performing this calibration , be sure to remove the Glass used in the Camera Offset (Gl ass) Calibration from the Fix Camera. …

100%1 / 632
14-53
Machine Calibration
The measurement result can be confirmed in the Head Offset dialog box.
Memo The reference values for the calibration of the Camera Offset is as
follows.
Gantry 1
Offset X : -189.5 ~ -187.5 (mm)
Offset Y : -1.0 ~ 1.0 (mm)
Calibration using Fix Camera Hole (Optional)
This process is performed after calibrating with the Calibration Glass.
This calibration is performed in order to use the “Runtime Calibration” function. The
measured values are not reflected in the system calibration data, but are used only as
data necessary for the “Runtime Calibration” function. Perform calibration only when
the “Runtime Calibration” function is used.
Memo To activate the <9-A. Camera Offset (Hole)> button, the System
Constant setting must be made first. Please contact our CS or local
representative office.
Memo To use the “Runtime Calibration” function, System Constant setting
should first be performed. Please contact our CS or local
representative office.
14-54
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
Caution Before performing this calibration, be sure to remove the
Glass used in the Camera Offset (Glass) Calibration from
the Fix Camera.
1. Click the <9-A. Camera Offset (Hole)> button.
2. Click the <Next> button.
3. The message “Move To Center Position Of [Fix 1] Camera. To Move,
Click[Next].” appears in the message window.
14-55
Machine Calibration
Click the <Next> button to move the fiducial camera to the fix camera hole
position.
4. Then the message “1. First, Select Move Camera and Adjust Light Level. 2. After
then, Select Fix Camera and Adjust Light Level. 3. To Calibrate, Click [Next].”
appears.
Select "Fid Cam1" in the <Target Camera> combo box and click the <Light ...>
button to adjust the brightness of the lighting so that the Fix Camera Hole shown
in the SM Vision window is clearly visible.
Then, select "Fix Cam1" in the <Target Camera> combo box, and follow the same
procedure as for the fiducial camera.
When you have finished adjusting the brightness of the lighting, click the <Next>
button.