18-6 Next Generation, Multi-Functional Plac er DECAN S1 Administrator’s Guide  <Close> button Closes the screen. 18.1.2. Head Displays the operation data for each head. Sh ows the overall statistics information re…

100%1 / 632
18-5
Production Information Management
Indicates the count of machine stop performed by an error during automatic
production.
<Print To File> button
Saves the placement information related with PCB production in the assigned folder
(C:\ SmartSM\Pdinfo) in text file(*.txt) format.
<PPM<->%> button
Converts the indicated unit. (PPM<->%)
<Reset> button
Initializes all the indication information.
18-6
Next Generation, Multi-Functional Placer DECAN S1 Administrator’s Guide
<Close> button
Closes the screen.
18.1.2. Head
Displays the operation data for each head. Shows the overall statistics information related
with placement.
<Head> column
Displays the total head number.
<Pickup> column
Displays the total number of components picked up.
<Place> column
Displays the total number of components placed.
<Error> column
Indicates the number of part placement failures after recognizing the picked up parts
using ‘Vision’.
<Error (PPM)> column
Recognize the picked part by using the vision system and indicate the non-placement
error in PPM unit.
<PostPick Miss> column
After parts are adsorbed, the number of failures to mount the parts is displayed.
<PrePlace Miss> column
Before parts are adsorbed, the number of failures to mount the parts is displayed.
18-7
Production Information Management
<Part NG> column
Indicates the number of part recognition failures using ‘Vision’ after pickup of parts.
<Dump> column
Indicates the number of times part dumping has been performed by the corresponding
head.
18.1.3. Feeder
Displays the operation information of each feeder.
<Feeder> column
Indicates the information on the slot where the feeder is installed and the parts are
supplied.
<Pickup> column
Displays the number of components picked up from the corresponding feeder.
<Place> column
Displays the number of components placed from the corresponding feeder.
<Error> column
Displays the number of components placed from the corresponding feeder.
<Error (PPM)> column
Indicate the feeder error, which caused the fed parts not to be placed, in the PPM unit.
<PostPick Miss> column
After parts are adsorbed, the number of failures to mount the parts is displayed.
<PrePlace Miss> column