Test Research, Inc. TR7007M SII User Guide – Hardware 3 2 HCI & PLC The Human - Computer Interface (HCI) is mainly used to set the required testing modes (settings such as Stand - Alone or Inline, whether the Loader …

Test Research, Inc.
2 TR7007M SII User Guide – Hardware
Figure 1: System Front View & Important Parts
The Operating and Storage environmental parameters for TR7007 SII systems are listed in
the following table.
Operating
Storage
Ambient Temperature:
0-40°C (32-104°F)
-40-66°C (-40-151°F)
Max. Temperature Gradient:
10°C/hour (18°F/hour)
10°C/hour (18°F/hour)
Relative Humidity:
20-80% non-condensing
Up to 95% non-condensing
Max. Humidity Gradient:
10%/hour
10%/hour
Max. Wet Bulb Temperature:
25°C (77°F)
46°C (115°F)
Max. Dew Point Temperature:
2°C (36°F)
2°C (36°F)
Figure 2: Operating & Storage Environment for TR7007 SII Systems
Signal Tower
Monitor
Mouse and
Keyboard
Power Switch
Emergency
Stop
HCI
Adjustable
Feet
Front Door

Test Research, Inc.
TR7007M SII User Guide – Hardware 3
2 HCI & PLC
The Human-Computer Interface (HCI) is mainly used to set the required testing modes
(settings such as Stand-Alone or Inline, whether the Loader or Unloader are present, etc.).
The Programmable Logic Controller (PLC) is mainly used to control the PCB I/O Board
Holder as well as exchange sampling or Pass/Fail signals (through the RS-232 cable);
usually when the machine is set to In-Line mode there will be a greater chance of I/O board
issues or loader/unloader error. The function of HCI and PLC will be described in the
following chapters.

Test Research, Inc.
4 TR7007M SII User Guide – Hardware
3 HCI OPERATING INSTRUCTIONS
3.1 Initial Screen
Figure 3 below shows the Startup display. Power on the AOI system, wait approximately 5
seconds, and the display will jump to the starting page. Five options will be shown:
Figure 3: Startup Display
3.1.1 Mode Set
After choosing [Mode Set] from Figure 3
the screen below will appear. Choose between
three modes: [INLINE], [Stand Alone ] or [ Test]. The setting will be automatically stored
during shut down, and automatically loaded at the next power on.
Figure 4: Mode Settings
INLINE: Connect to external manufacturing line equipment for inline inspection.
INLINE (hiding [BYPASS] button on Standby screen): Press and hold the hidden button at
the lower right corner of the display for at least 2 seconds, then press the [INLINE] button.
The button turns to black ([ INLINE]).Then, select the [INLINE] button to hide the
[BYPASS] button on the Standby screen (
Figure 37).
STAND ALONE: The TR7007 SII is not connected to external equipment for testing. This
mode requires manual loading and unloading.
TEST: Single board test, does not connect to external equipment for inline testing. User
may choose the number of test cycles.
3.1.2 I/O SET
Choosing different modes in MODE SET will result in different I/O settings. The settings are
explained in this section. Settings will be automatically stored during shut down, and
automatically loaded at the next power on.