Test Research, Inc. 28 TR7007 M SII User Guide – Hardware 3.5 PLC Program Replacement 1) First connect the PLC - P C data cable properly, wit h the PS2 connect or connected to the rear of the PCI, and the RS232 connected…

100%1 / 96
Test Research, Inc.
TR7007M SII User Guide Hardware 27
5) After backup, close the original HCI interface software. Then click on [File] to open the
HCI interface program (*.iop) to be updated as shown in the figure below.
Figure 72: Open HCI Interface Program
6) Click on the File and select Transfer. In the [Transfer Data] dialog, select [All Data],
[Transfer Data After Clear GT Screen] and [GTWIN->GT]. Click [OK] as shown in the
figure below.
Figure 73: Transfer Data Options
7) Wait for the PC to transfer the data to the HCI (this may take some time, please wait
patiently), and the program will be updated.
Test Research, Inc.
28 TR7007M SII User Guide Hardware
3.5 PLC Program Replacement
1) First connect the PLC-PC data cable properly, with the PS2 connector connected to the
rear of the PCI, and the RS232 connected to Main PC COM1.
2) Open the Program Files and select FPWIN GR.
3) Enter the [FPWIN GR] software program and click on [Upload from PLC] as shown in the
figure below.
Figure 74: FPWIN-GR Select Upload from PLC
4) After uploading, click on [File] and select [Save] to make a backup of the original files as
shown in the figure below:
Figure 75: FPWIN-GR Backup Original Files
Test Research, Inc.
TR7007M SII User Guide Hardware 29
5) After backup, close the original PLC program. Then click on File to Open the PLC
interface program (*.fp) you wish to update as shown in the figure below.
Figure 76: FPWIN-GR Select Update Program
6) Click on the icon in the menu [Download to PLC], click [Yes] to confirm overwrite of
existing program as shown in the picture below:
Figure 77: FPWIN-GR Confirm Overwrite
7) Wait for the PC to transfer the data to the PLC, and the program will be updated.