Test Research, Inc.
TR7007M SII User Guide – Hardware 9
Light
In Figure 7: Other Settings Page 1
, select [LIGHT] to set the Three Colored Indicator Light
Display (see the following figure). First press to highlight the status position to set, then
select the lights to display for that step. If no settings are made then the factory defaults will
be used.
Figure 16: Indicator Lights
Test Count
In Figure 7: Other Settings Page 1
, select [TEST COUNT] to set the number of test cycles
to perform in TEST mode (below figure). If set to 0, then the number of cycles is infinite.
Press [BACK] to return to the Startup page (
Figure 3).
Figure 17: Set Test Count
Other Settings Page 2
In Figure 7: Other Settings Page 1
, select [NEXT] to display page 2 of the Settings menu.
Options available are:
Figure 18: Other Settings Page 2
BUZZER: Confirm if an alarm buzzer will sound to warn the operator if the Unloader is
not ready to avoid causing a board blockage at the Loader.

Test Research, Inc.
10 TR7007M SII User Guide – Hardware
Figure 19: Confirm Buzzer
IN AND OUT: Choose simultaneous In and Out to load a board while another board is
being unloaded (the test board length must be less than 200mm or there may be an
issue with board overlap). If NO is chosen then a board must be fully unloaded before
another is loaded.
Figure 20: Choose Simultaneous In & Out
Next Page: From Figure 18: Other Settings Page 2, select [NEXT PAGE]. The five
options available are:
Figure 21: Other Settings Page 3
HIGH SPEED:This is the normal I/O speed. Press [ENTER] at Figure 22 to set
this speed. The speed range has an upper limit of 2600PPS and lower limit of
100PPS. Default setting is 2000.
Figure 22: High Speed Setting
BYPASS SPEED: This is the bypass speed. Press [ENTER] at the following
figure to set this speed. The speed range has an upper limit of 2600PPS and
lower limit of 100PPS. Default setting is 2000.

Test Research, Inc.
TR7007M SII User Guide – Hardware 11
Figure 23: Bypass Speed Setting
LOW SPEED: This is the reduced speed. Press [ENTER] at the following figure
to set this speed. The speed range has an upper limit of 1000PPS and lower
limit of 20PPS. The default is 100.
Figure 24: Low Speed Setting
LANGUAGE: Choose Chinese or English user interface on the following screen.
Once selection has been made it will be automatically saved and does not need
to be set again the next time the machine is turned on.
Figure 25: Select Language
• Machine Type and Barcode Testing Settings: Press the hidden buttons
located in Figure 25
separately (within a 2 second interval) to display the
machine type and barcode setting display as shown in Figure 28: Set
Machine Type.
Figure 26: Select Language – Choosing MachineType