2 Functions for the Adjustment of the Machine User Manual Test Program SITEST
2.5 Conveyor Functions Software Version 405.xx Issue 01/99
2 - 30
NOTE
Concerning all functions of the width adjustment option, the lifting table must automatically move
down
!
2
If you wish to calibrate the conveyor width, adjust the width of the currently active conveyor to 100 mm
using the
Adjust conveyor width
function, prior to the calibration procedure.
Check that a 100 mm-wide PCB can be transported through the entire conveyor system without any
problem.
Click on the
Calibrate conveyor width
button and acknowledge the dialog box displayed by clicking on
OK
. The function will be performed on the selected conveyor.
If you wish to carry out further width adjustment functions, click on the corresponding button for the
desired function.
User Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 405.xx Issue 01/99 2.6 Component Table Functions
2 - 31
2.6 Component Table Functions
If you wish to test the functions of the component table, click - in the main view - on the icon for
"Table left" or on the icon for "Table right" and subsequently (if required) on the icon to
switch to the "Table functions" display.
Fig. 2.6.1 "Table functions" Display
The following functions are available in this display:
Actuate tape cutter to actuate the tape cutting unit
Set vibratory feeder output to activate the linear feeder
Set table output to set the output
Change to enter the track number
Click on the Change button in the "Current track" field.
The "Track" input box opens.
If you wish to test, for example, a specific linear feeder, enter the number of the track on which the
feeder is set up and confirm your entry by clicking on Accept
.
2 Functions for the Adjustment of the Machine User Manual Test Program SITEST
2.6 Component Table Functions Software Version 405.xx Issue 01/99
2 - 32
Select the function you wish to test for the component that is set up on the track entered or that can be
addressed via the address of this track, e.g.
Set vibratory feeder output
for the linear feeder that is set
up on the track entered.
A dialog box opens, and the selected function will continue to be executed until you click on the
Cancel
button in the dialog box.
NOTE
The toolbar in the "Table functions" display contains the icon. It is used to switch to the "Pick-up position
track 1 and track 120" display. The latter contains all functions required for calibrating the pick-up position (see
chapt. 3, section 3.13).