3 Calibration Functions User Manual Test Program SITEST
3.5 Calibration of the Machine Zero Point Software Version 405.xx Issue 01/99
3 - 12
Click on the
Approach
button in the "Machine zero point" field.
The active gantry moves the PCB camera over the measuring hole for the MA zero point.
The screen display is switched to the PCB camera.
Check whether the measuring hole for the machine zero point is visible in the camera’s field of view.
NOTE
If the measuring hole is not visible in the camera’s field of view, the value for the zero point correction
has to be changed (see chapt. 2, section 2.1.1, page 2 - 5).
Press
ESC
to return the screen display to the normal program mode.
Click on the
Calibrate
button in the "Machine zero point" field.
The calibration of the machine zero point will now be performed. The position values for x and y are dis-
played in the "Machine zero point" field.
Click on the icon to return to the main view.
User Manual Test Program SITEST 3 Calibration Functions
Software Version 405.xx Issue 01/99 3.6 Verification of the Calibration Tool Position
3 - 13
3.6 Verification of the Calibration Tool Position
In the main view click on the icon (for gantry 1 of SIPLACE 80S-20/S-23) or the icon (for the
gantry of SIPLACE 80F
4
/80F
5
)
to switch the screen display to the "Gantry" display (see Fig. 0.3.4).
Click on the icon to reach the "Calibrate positions" display (see Fig. 3.5.1).
Click on the
Approach
button in the "Calibration tool pos." field.
The active gantry moves the PCB camera over the calibration tool position. The screen display is
switched to the PCB camera.
Check whether the calibration tool fiducial is visible in the PCB camera’s field of view.
Press
ESC
to return the screen display to the normal program mode.
3 Calibration Functions User Manual Test Program SITEST
3.6 Verification of the Calibration Tool Position Software Version 405.xx Issue 01/99
3 - 14