User Manual Test Program SITEST 1 General Functions Software Version 405.xx Issue 01/99 1.3 Machine Configuration 1 - 9 – Head type (unique to SIPLAC E 80F 4 ) 12-nozz le head revolver he ad with 12 sleeves 6-nozzle h ea…

1 General Functions User Manual Test Program SITEST
1.3 Machine Configuration Software Version 405.xx Issue 01/99
1 - 8
NOTES
The selection of the conveyor type and the fixed conveyor side also defines the location of the calibration
tool pocket, the MA zero point and the PCB reference corners during the performance of calibration pro-
cedures (see also Fig. 3.2.1 in chapt. 3).
The selection of the conveyor type and the fixed conveyor side is carried out one single time during the
initial start-up before any calibration, transport and mapping functions are performed, or whenever a new
conveyor is installed.
Only since the activation of the "Dual conveyor" conveyor type has it been possible to select from the tool-
bar in the main view the right side (Transport 1) or the left side (Transport 2) of the dual conveyor for given
functions to be carried out (see chapt. 2, section 2.5).
1
–
Transport mode
Standard PCB (up to 460 mm) Setting for the assembly of PCBs with a length of 50 - 460 mm
PCBs may be located on the input, center and output conveyors.
Long PCB (up to 508 mm) Setting for the assembly of PCBs with a length of 50 - 508 mm
The individual PCBs are conveyed to the center conveyor with
a time delay.
–
Fixed conveyor side
Right The fixed side of the conveyor is located on the right (as seen in the
direction of travel).
Left The fixed side of the conveyor is located on the left (as seen in the
direction of travel).
NOTE
If the conveyor type was changed from single conveyor to dual conveyor (or vice versa) and the fixed con-
veyor side selected and stored, the positions of the MA zero point, the calibration tool and the PCB reference
corner need to be recalibrated as they were assigned default values. In the case of the dual conveyor, the
nozzle changers for the revolver head and IC head need to be recalibrated in addition.
1
–
Ceramic substrate centering
None no ceramic substrate centering
Mechanical centering station mechanical ceramic substrate centering
Additional PCB camera illumination optical ceramic substrate centering
mechanically and optically mech. and optical ceramic substrate centering
– Flux (unique to SIPLACE 80F
4
/80F
5
)
with flux dispenser flux dispenser
Without flux dispenser no flux dispenser

User Manual Test Program SITEST 1 General Functions
Software Version 405.xx Issue 01/99 1.3 Machine Configuration
1 - 9
–
Head type
(unique to SIPLACE 80F
4
)
12-nozzle head revolver head with 12 sleeves
6-nozzle head revolver head with 6 sleeves
–
Head type
(unique to SIPLACE 80F
5
)
6-nozzle head revolver head with 6 sleeves
6-nozzle head with FC camera revolver head with 6 sleeves and flip chip camera
–
Coplan
(only SIPLACE 80F
4
/80F
5
)
not available no coplanarity module fitted
Coplan LCM 150 with coplanarity module, type LCM 150
Coplan ILD 2000 with coplanarity module, type ILD 2000
NOTE
If the Coplan LCM 150 or Coplan ILD 2000 option was newly selected and the configuration change
saved, the coplanarity module must be calibrated (see chapt. 3, section 3.11).
1 General Functions User Manual Test Program SITEST
1.3 Machine Configuration Software Version 405.xx Issue 01/99
1 - 10