00191332-01.pdf - 第52页
1 General Functions User Manual Test Program SITEST 1.3 Machine Configuration Software Version 405.xx Issue 01/99 1 - 10

User Manual Test Program SITEST 1 General Functions
Software Version 405.xx Issue 01/99 1.3 Machine Configuration
1 - 9
–
Head type
(unique to SIPLACE 80F
4
)
12-nozzle head revolver head with 12 sleeves
6-nozzle head revolver head with 6 sleeves
–
Head type
(unique to SIPLACE 80F
5
)
6-nozzle head revolver head with 6 sleeves
6-nozzle head with FC camera revolver head with 6 sleeves and flip chip camera
–
Coplan
(only SIPLACE 80F
4
/80F
5
)
not available no coplanarity module fitted
Coplan LCM 150 with coplanarity module, type LCM 150
Coplan ILD 2000 with coplanarity module, type ILD 2000
NOTE
If the Coplan LCM 150 or Coplan ILD 2000 option was newly selected and the configuration change
saved, the coplanarity module must be calibrated (see chapt. 3, section 3.11).
1 General Functions User Manual Test Program SITEST
1.3 Machine Configuration Software Version 405.xx Issue 01/99
1 - 10

User Manual Test Program SITEST 1 General Functions
Software Version 405.xx Issue 01/99 1.4 Reference Run
1 - 11
1.4 Reference Run
Prior to starting to work with the test program it is necessary to perform a reference run of the gantry axes, the
head axes and, where available, also of the WPC axes.
1.4.1 Overall Reference Run
● In the main view click on the
Overall reference run
button.
The reference run will be performed for all head and gantry axes.
1.4.2 Head and Gantry Reference Run of the Active Gantry
Example: Gantry, SIPLACE 80F
4
/80F
5
● In the main view click on the icon and then (if required) the icon in order to reach the "Gantry
functions" display (see Fig. 0.3.4).
● Click on the
Head reference run
button.
The reference run will be performed for all axes of the revolver head and the IC head.
● Following the head reference run, click on the
Gantry reference run
button.
The gantry axes will perform the reference run.
NOTE
The steps described above also apply to gantries 1 and 2 of SIPLACE 80S-20/S-23.
The reference run will be performed for the head and gantry axes associated with the gantry selected.
1
1.4.3 Reference Run of RV Head
Example: Revolver head 1, SIPLACE 80S-20/S-23
● In the main view click on the icon and then (if required) the icon in order to reach the
"RV head functions" display (see Fig. 0.3.5).
● Click on the Head reference run button.
The reference run will be performed for all axes of the revolver head of gantry 1.
● If you wish to close the nozzles and move the (center) sleeves to the 0-degree position, click on the
Swivel out segments / close noz. button.