3 Calibration Functions User Manual Test Program SITEST
Software Version 405.xx Issue 01/99
3 - 2
User Manual Test Program SITEST 3 Calibration Functions
Software Version 405.xx Issue 01/99 3.1 Preparation for the Performance of the Calibration Functions
3 - 3
3.1 Preparation for the Performance of the Calibration
Functions
In the main view click on the
Overall reference run
button to have all gantry and head axes perform a
reference run.
Make sure that nozzles are fitted to all (center) sleeves of the revolver heads, i.e.
nozzle type
756
to the 12-nozzle revolver head,
nozzle type
720
to the 6-nozzle revolver head
,
and a nozzle of the type
416
to the IC head of SIPLACE 80F
4
/80F
5
.
NOTE
When you perform the calibration of the machine, the gantry that is not currently required will auto-
matically be moved to the park position.
3
Place the calibration tool into the "calibration piece pocket" (see Fig. 3.12.1).
NOTE
The calibration tool must be absolutely free of contamination and is to be placed into the "calibration tool
pocket" with the imprint of the fiducial structure facing down.
3
In the main view select the desired gantry by clicking on the corresponding icon.
NOTE
If the calibration activities are performed using the
Calibrate machine...
function, a selection of the gantry
is not required.
3
3 Calibration Functions User Manual Test Program SITEST
3.1 Preparation for the Performance of the Calibration Functions Software Version 405.xx Issue 01/99
3 - 4