User Manual Test Program SITEST 3 Calibration Functions Software Version 405.xx Issue 01/99 3.10 Calibration of t he Flip-Chip Camera (SIPLACE 80F4/80F5) 3 - 25 3.10 Calibration of the Flip-Chip Camera (SIP LA CE 80F 4 /…
3 Calibration Functions User Manual Test Program SITEST
3.9 Calibration of the RV Nozzle Changer Software Version 405.xx Issue 01/99
3 - 24

User Manual Test Program SITEST 3 Calibration Functions
Software Version 405.xx Issue 01/99 3.10 Calibration of the Flip-Chip Camera (SIPLACE 80F4/80F5)
3 - 25
3.10 Calibration of the Flip-Chip Camera
(SIPLACE 80F
4
/80F
5
)
● Carry out the preparatory steps proceeding as described in section 3.1.
● In the "IC head" display (see Fig. 0.3.6) click on the icon to switch to the "Flip-chip camera"
display.
Fig. 3.10.1 "Flip-chip camera" Display
Overview of the functions:
– Calibr. flip-chip camera to calibrate the Flip-Chip camera
– Illumination values... to display the illumination values
(Normally, the illumination values do not
need to be changed.
Changing the values in a non-expert manner will lead to incorrect
calibration results).
– Display camera coefficient... to display the Flip-Chip camera values determined
– Display focus position... to display the camera position and focus height determined

3 Calibration Functions User Manual Test Program SITEST
3.10 Calibration of the Flip-Chip Camera (SIPLACE 80F4/80F5) Software Version 405.xx Issue 01/99
3 - 26
● Click on the
Calibr. flip-chip camera
button.
The calibration of the Flip-Chip camera is now performed.
● If you wish to view the values determined after the completion of the calibration procedure, click on the
Display camera coefficient...
button.
● If you wish to view the values for the camera position and focus height, click on the
Display focus
position...
button.
NOTE
The x and y-values of the current camera position are also displayed in the "Camera position" field.
● Click on the icon to return to the main view.