00197279-03_SM_Glue-Feeder_EN.pdf - 第29页
Replacing Spare Parts 3.11.1 Removing the Cartridge Pipe Cartridge Pipe Service Manual SIPLACE Glue Feeder 29 3.11 3 . 1 1 C a r t r id g e P ip e Cartridge Pipe Required spare parts Cartridge p ipe, item no. 0308904 6-x…

Replacing Spare Parts
Heating Cable 3.10.2 Fitting the Heating Cable
28 Service Manual SIPLACE Glue Feeder
See also
3.8.2 Fitting the Right Side Cover [ ➙ 21]
► Run the heating cable in the cable duct, as shown in
the diagram.
► Plug the heating cable connector onto the heating.
► Fasten the left side cover (see "3.7.2 Fitting the Left
Side Cover" [ ➙ 20].
► Fasten the right side cover (see .

Replacing Spare Parts
3.11.1 Removing the Cartridge Pipe Cartridge Pipe
Service Manual SIPLACE Glue Feeder 29
3.11
3.11 Cartridge Pipe
Cartridge Pipe
Required spare parts
Cartridge pipe, item no. 03089046-xx
Tools and equipment required
▪ Spanner wrench, 8 mm
▪ Heating key (on the glue feeder)
▪ Disposable protective gloves
3.11.1
3.11.1 Removing the Cartridge Pipe
Removing the Cartridge Pipe
CAUTION
Poisonous and hazardous substances
To avoid direct contact with the glue, always wear protective gloves during this work.
► Place the glue feeder down on a firm surface.
► Hold the cartridge tightly with one hand.
► Turn the cartridge adapter anticlockwise by about
90°.

Replacing Spare Parts
Cartridge Pipe 3.11.1 Removing the Cartridge Pipe
30 Service Manual SIPLACE Glue Feeder
► Press the cartridge adapter towards the back and pull
it off.
► Unscrew the cartridge from the cartridge pipe thread.
► Unplug the heating connector from the nozzle heat
-
ing.