00197279-03_SM_Glue-Feeder_EN.pdf - 第68页

Replacing Spare Parts Manometer 3.17.1 Man ometer (Dispenser) 68 Service Manual SIPLACE Glue Feeder ► Remove the large brass nut with the stra ight push- fit connector. Use two fork wrenches for this: a size 14 fork wren…

100%1 / 96
Replacing Spare Parts
3.17.1 Manometer (Dispenser) Manometer
Service Manual SIPLACE Glue Feeder 67
Mark the hose connected to the top manometer with
adhesive tape.
Carefully place the glue feeder down on its left side.
Remove the hoses from the top and bottom manom
-
eters.
Remove the 4 screws marked. Use a size 1.5 Allen
key for this.
Lift the plate with the two manometers forwards and
out of the glue feeder frame.
Remove the two marked nuts. Use a size 7 fork
wrench for this.
Replacing Spare Parts
Manometer 3.17.1 Manometer (Dispenser)
68 Service Manual SIPLACE Glue Feeder
Remove the large brass nut with the straight push-fit
connector. Use two fork wrenches for this:
a size 14 fork wrench for below, to hold the screw,
a size 11 fork wrench for above, to loosen the brass
nut.
Once you have removed the brass nut (1), pull the fix
-
ture bracket sideways and off the manometer. (2)
Carefully press the manometer a little out of the cover
plate. (1)
Carefully pull the manometer fully out of the cover
plate. (2)
Replacing Spare Parts
3.17.1 Manometer (Dispenser) Manometer
Service Manual SIPLACE Glue Feeder 69
3.17.1.2
3.17.1.2 Fitting the Manometer (Dispenser)
Fitting the Manometer (Dispenser)
Carefully insert the manometer as far as possible into
the cover plate. (1)
Align the manometer vertically. (2)
Push the fixture bracket from the side onto the
manometer. (1)
Push the fixture bracket forwards, as far as possible
(end stop) and align it so that it is straight. (2)
Fasten the large brass nut with the straight push-fit
connector. Use two fork wrenches for this:
a size 14 fork wrench for below, to hold the screw,
a size 11 fork wrench for above, to tighten the brass
nut.