00197279-03_SM_Glue-Feeder_EN.pdf - 第70页

Replacing Spare Parts Manometer 3.17.1 Man ometer (Dispenser) 70 Service Manual SIPLACE Glue Feeder ► Faste n the fixtur e bracket wit h the two m arked nuts . Use a size 7 fork wrench for this. ► Fit the cover plate wit…

100%1 / 96
Replacing Spare Parts
3.17.1 Manometer (Dispenser) Manometer
Service Manual SIPLACE Glue Feeder 69
3.17.1.2
3.17.1.2 Fitting the Manometer (Dispenser)
Fitting the Manometer (Dispenser)
Carefully insert the manometer as far as possible into
the cover plate. (1)
Align the manometer vertically. (2)
Push the fixture bracket from the side onto the
manometer. (1)
Push the fixture bracket forwards, as far as possible
(end stop) and align it so that it is straight. (2)
Fasten the large brass nut with the straight push-fit
connector. Use two fork wrenches for this:
a size 14 fork wrench for below, to hold the screw,
a size 11 fork wrench for above, to tighten the brass
nut.
Replacing Spare Parts
Manometer 3.17.1 Manometer (Dispenser)
70 Service Manual SIPLACE Glue Feeder
Fasten the fixture bracket with the two marked nuts.
Use a size 7 fork wrench for this.
Fit the cover plate with the two manometers onto the
front of the glue feeder frame.
Make sure that the manometer (dispenser) is at the
top.
Fasten the cover plate with the 4 screws marked. Use
a size 1.5 Allen key for this.
Carefully place the glue feeder down on its left side.
Connect the hose marked with adhesive tape to the
top manometer (dispenser).
Connect the other hose to the bottom manometer
(cartridge).
Remove the adhesive tape from the marked hose.
Replacing Spare Parts
3.17.2 Manometer (Cartridge) Manometer
Service Manual SIPLACE Glue Feeder 71
3.17.2
3.17.2 Manometer (Cartridge)
Manometer (Cartridge)
Required spare parts
Manometer 4K8-4P assembly, item no. 03094560-xx
Required tools
Phillips screwdriver
Allen key, size 1.5
Open-ended wrench, size 7
Open-ended wrench, size 11
Open-ended wrench, size 14
3.17.2.1
3.17.2.1 Removing the Manometer (Cartridge)
Removing the Manometer (Cartridge)
The manometer (cartridge) is removed using the same procedure as that for removing the manometer
(dispenser), see "3.17.1.1 Removing the Manometer (Dispenser)" [ 66].
Only difference:
remove the bottom manometer instead of the top one.
3.17.2.2
3.17.2.2 Fitting the Manometer (Cartridge)
Fitting the Manometer (Cartridge)
The manometer (cartridge) is fitted using the same procedure as that for fitting the manometer (dispens
-
er), see "3.17.1.2 Fitting the Manometer (Dispenser)" [ 69].
Only difference:
fit the bottom manometer instead of the top one.
Carefully place the glue feeder down on its right side.
Fasten the marked screw. Use a Phillips screwdriver
for this.
Now fasten the right side cover (see "3.8.2 Fitting the
Right Side Cover" [ ➙ 21]).