00197279-03_SM_Glue-Feeder_EN.pdf - 第55页
Replacing Spare Parts 3.15.2 Fitting the Jet Valve P-DOT Jet Valve P-DOT Service Manual SIPLACE Glue Feeder 55 See also 3.8.2 Fit ting the R ight Side Cove r [ ➙ 21] ► Use the two marked screws t o fasten the fixture…

Replacing Spare Parts
Jet Valve P-DOT 3.15.2 Fitting the Jet Valve P-DOT
54 Service Manual SIPLACE Glue Feeder
► Insert the heating connector into the nozzle heating,
up to the stop.
► As shown in the diagram, insert the fixture block into
the glue feeder.
► Use the two marked screws to fasten the fixture block
to the frame (at the top). Use a size 2 Allen key for
this.
► Run the heating cable in the fixture block duct, as
shown in the diagram.

Replacing Spare Parts
3.15.2 Fitting the Jet Valve P-DOT Jet Valve P-DOT
Service Manual SIPLACE Glue Feeder 55
See also
3.8.2 Fitting the Right Side Cover [ ➙ 21]
► Use the two marked screws to fasten the fixture block
to the frame (at the bottom). Use a size 2.5 Allen key
for this.
► Use the 4 marked screws to fasten the cover plate to
the frame. Use a size 1.5 Allen key for this.
► Fasten the right side cover (see .

Replacing Spare Parts
Jet Valve P-DOT 3.15.3 Jet Valve P-DOT - Setting the Jet Plunger
56 Service Manual SIPLACE Glue Feeder
3.15.3
3.15.3 Jet Valve P-DOT - Setting the Jet Plunger
Jet Valve P-DOT - Setting the Jet Plunger
You need the special plunger setting measuring system for setting the jet plunger.
3.15.3.1
3.15.3.1 Checking the Jet Plunger Setting
Checking the Jet Plunger Setting
Plunger setting measuring system
1. Large pointer
Scale in 1/100 mm
2. Small pointer
Scale in 1 mm
3. Setting ring for positioning the scale 1/100 mm
4. Connection nut
NOTICE
Order
The plunger setting measuring system can be ordered with the item number MS1010 from Liq
-
uidyn.
► Remove the nozzle heating (see section "3.9.1 Re
-
moving the Nozzle Heating" [ ➙ 22]).
► Before you fit the measuring system, turn the setting
ring until the large pointer points to the 0.