00197279-03_SM_Glue-Feeder_EN.pdf - 第54页
Replacing Spare Parts Jet Valve P-DOT 3.15.2 Fitting the Jet Valve P-DOT 54 Service Manual SIPLACE Glue Feeder ► Insert the heating connector into the nozzle heating, up to the stop. ► As shown in the diagram, inse rt th…

Replacing Spare Parts
3.15.2 Fitting the Jet Valve P-DOT Jet Valve P-DOT
Service Manual SIPLACE Glue Feeder 53
► Align the jet valve.
The right side of the jet valve must be flush with the
frame.
The nozzle should be at the same height as the refer
-
ence sheets on the front of the glue feeder.
► Once the jet valve has been correctly aligned, tighten
the two screws.
► Insert the hose as far as possible into the com
-
pressed air connection.

Replacing Spare Parts
Jet Valve P-DOT 3.15.2 Fitting the Jet Valve P-DOT
54 Service Manual SIPLACE Glue Feeder
► Insert the heating connector into the nozzle heating,
up to the stop.
► As shown in the diagram, insert the fixture block into
the glue feeder.
► Use the two marked screws to fasten the fixture block
to the frame (at the top). Use a size 2 Allen key for
this.
► Run the heating cable in the fixture block duct, as
shown in the diagram.

Replacing Spare Parts
3.15.2 Fitting the Jet Valve P-DOT Jet Valve P-DOT
Service Manual SIPLACE Glue Feeder 55
See also
3.8.2 Fitting the Right Side Cover [ ➙ 21]
► Use the two marked screws to fasten the fixture block
to the frame (at the bottom). Use a size 2.5 Allen key
for this.
► Use the 4 marked screws to fasten the cover plate to
the frame. Use a size 1.5 Allen key for this.
► Fasten the right side cover (see .