Replacing Spare Parts
3.15.2 Fitting the Jet Valve P-DOT Jet Valve P-DOT
Service Manual SIPLACE Glue Feeder 53
Align the jet valve.
The right side of the jet valve must be flush with the
frame.
The nozzle should be at the same height as the refer
-
ence sheets on the front of the glue feeder.
Once the jet valve has been correctly aligned, tighten
the two screws.
Insert the hose as far as possible into the com
-
pressed air connection.
Replacing Spare Parts
Jet Valve P-DOT 3.15.2 Fitting the Jet Valve P-DOT
54 Service Manual SIPLACE Glue Feeder
Insert the heating connector into the nozzle heating,
up to the stop.
As shown in the diagram, insert the fixture block into
the glue feeder.
Use the two marked screws to fasten the fixture block
to the frame (at the top). Use a size 2 Allen key for
this.
Run the heating cable in the fixture block duct, as
shown in the diagram.
Replacing Spare Parts
3.15.2 Fitting the Jet Valve P-DOT Jet Valve P-DOT
Service Manual SIPLACE Glue Feeder 55
See also
3.8.2 Fitting the Right Side Cover [ ➙ 21]
Use the two marked screws to fasten the fixture block
to the frame (at the bottom). Use a size 2.5 Allen key
for this.
Use the 4 marked screws to fasten the cover plate to
the frame. Use a size 1.5 Allen key for this.
Fasten the right side cover (see .