00197279-03_SM_Glue-Feeder_EN.pdf - 第50页

Replacing Spare Parts Jet Valve P-DOT 3.15.2 Fitting the Jet Valve P-DOT 50 Service Manual SIPLACE Glue Feeder 3.15.2 3 . 1 5 . 2 F it t in g t h e J e t V a lv e P - D O T Fitting the Jet Valve P-DOT ► Rem ove the dispe…

100%1 / 96
Replacing Spare Parts
3.15.1 Removing the Jet Valve P-DOT Jet Valve P-DOT
Service Manual SIPLACE Glue Feeder 49
Lift the jet valve out of the glue feeder.
Remove the screw fastening the power supply to the
jet valve. (1)
Use a Phillips screwdriver for this.
Unplug the power supply from the jet valve. (2)
Insert the heating key into the union nut, screw in
loosely and then remove the key. (1)
Lift the nozzle heating off the jet block. (2)
Replacing Spare Parts
Jet Valve P-DOT 3.15.2 Fitting the Jet Valve P-DOT
50 Service Manual SIPLACE Glue Feeder
3.15.2
3.15.2 Fitting the Jet Valve P-DOT
Fitting the Jet Valve P-DOT
Remove the dispenser nozzle from the jet block.
Loosen the screwed connection with the help of an 8
mm open-ended wrench.
Remove the cartridge pipe.
Place the cartridge pipe from behind onto the thread
of the jet block.
Use a size 8 mm open-ended wrench to loosely fas
-
ten the cartridge pipe in a clockwise direction.
Replacing Spare Parts
3.15.2 Fitting the Jet Valve P-DOT Jet Valve P-DOT
Service Manual SIPLACE Glue Feeder 51
Align the cartridge pipe centrally and straight in rela
-
tion to the back, so that the cartridge can be correctly
screwed into place.
Fix the cartridge pipe with one hand in this position
and then screw the lock tight.
Fit the dispenser nozzle onto the top of the jet block.
Place the nozzle heating onto the jet block and align
this straight on the feed pipe. (1)
Place the union nut into the nozzle heating and
tighten. (2) Use the heating key for this.