00197279-03_SM_Glue-Feeder_EN.pdf - 第87页

Replacing Spare Parts 3.23.1 Removing the EDIF EDIF Secondary Assembly Service Manual SIPLACE Glue Feeder 87 3.23 3 . 2 3 E D I F S e c o n d a r y A s s e m b ly EDIF Secondary Assembly Required spare parts EDIF seconda…

100%1 / 96
Replacing Spare Parts
Cartridge Holder Assembly 3.22.2 Fitting the Cartridge Holder
86 Service Manual SIPLACE Glue Feeder
3.22.2
3.22.2 Fitting the Cartridge Holder
Fitting the Cartridge Holder
As shown in the diagram, carefully fit the cartridge
holder onto the glue feeder.
Make sure that you position the cartridge holder so
that you can screw the cartridge to the cartridge pipe
afterwards.
Use the two marked screws to fasten the cartridge
holder. Use a size 2.5 Allen key for this.
1. Fasten the first screw loosely so that the cartridge
base can still move a little, giving you room to fit the
second screw.
2. Tighten the second screw.
3. Now tighten the first screw.
Replacing Spare Parts
3.23.1 Removing the EDIF EDIF Secondary Assembly
Service Manual SIPLACE Glue Feeder 87
3.23
3.23 EDIF Secondary Assembly
EDIF Secondary Assembly
Required spare parts
EDIF secondary assembly. /X2x8, item no. 03065209-xx
Required tools
Flat bladed (slotted) screwdriver
Allen key size 2
3.23.1
3.23.1 Removing the EDIF
Removing the EDIF
Place the feeder on a stable, level and clean surface.
Remove the left side cover (see "3.7.1 Removing the
Left Side Cover" [ ➙ 20].
Remove the two collar screws. (1) Use a slotted
screwdriver to help you.
Remove the screw (2) which fastens the connector to
the board. Use a size 2 Allen key for this.
Lift the connector carefully off the board and remove
the EDIF.
Check that the EDIF foam sealing at the top and bot
-
tom is not damaged or worn and replace if required.
Replacing Spare Parts
EDIF Secondary Assembly 3.23.2 Fitting the EDIF
88 Service Manual SIPLACE Glue Feeder
3.23.2
3.23.2 Fitting the EDIF
Fitting the EDIF
Check the compression springs for damage and re
-
place if necessary.
Insert the EDIF and fasten into place with the two col
-
lar screws (1). Use a slotted screwdriver for this.
Make sure that the two compression springs point to
the front and are not distorted.
Check whether the EDIF springs back to the front if
slight pressure is applied to it.
If the EDIF does not spring back, loosen the collar
screws (1) and check or correct the position of the
two compression springs (see above).
Place the connector on the main board, ensuring the
alignment pins engage in the holes.
Carefully screw the connector to the board. (2) Use a
size 2 Allen key for this.
Fasten the left side cover (see "3.7.2 Fitting the Left
Side Cover" [ ➙ 20].