Replacing Spare Parts 3.16.2 Pressure Control Valve (Cartridge) Pressure Control Valves Service Manual SIPLACE Glue Feeder 65 3.16.2.2 3 . 1 6 . 2 . 2 F it t in g t h e P r e s s u r e C o n t r o l V a lv e ( C a r t r …

Replacing Spare Parts
Pressure Control Valves 3.16.2 Pressure Control Valve (Cartridge)
64 Service Manual SIPLACE Glue Feeder
3.16.2
3.16.2 Pressure Control Valve (Cartridge)
Pressure Control Valve (Cartridge)
Required spare parts
Pressure control valve LR-M7-D-O-MICRO-B assembly, item no. 03094558-xx
Required tools
▪ Open-ended wrench, size 24
3.16.2.1
3.16.2.1 Removing the Pressure Control Valve (Cartridge)
Removing the Pressure Control Valve (Cartridge)
► Remove the right side cover (see "3.8.1 Removing
the Right Side Cover" [ ➙ 21])
► Pull the cover on the pressure control valve up and
off. (1)
► Remove the nut fastening the pressure control valve.
Use a size 24 fork wrench for this. (2)
► Remove the hoses on the left and right from the pres
-
sure control valve connections.
► Carefully pull the pressure control valve vertically
downwards and out of the glue feeder frame.

Replacing Spare Parts
3.16.2 Pressure Control Valve (Cartridge) Pressure Control Valves
Service Manual SIPLACE Glue Feeder 65
3.16.2.2
3.16.2.2 Fitting the Pressure Control Valve (Cartridge)
Fitting the Pressure Control Valve (Cartridge)
► As shown in the diagram, plug the pressure control
valve into the glue feeder frame and align it so that it
is straight.
► Push the hoses as far as possible into the connec
-
tions on the pressure control valve.
Make sure you assign them correctly.
► Fasten the pressure control valve with a nut. Use a
size 24 fork wrench for this. (1)
When fastening the nut, hold the pressure control
valve tight, so that it does not turn.
► Fit the cover as far as possible onto the pressure con
-
trol valve. (2)
► Fasten the right side cover (see "3.8.2 Fitting the
Right Side Cover" [ ➙ 21])

Replacing Spare Parts
Manometer 3.17.1 Manometer (Dispenser)
66 Service Manual SIPLACE Glue Feeder
3.17
3.17 Manometer
Manometer
3.17.1
3.17.1 Manometer (Dispenser)
Manometer (Dispenser)
Required spare parts
Manometer 4K8-10P assembly, item no. 03094559-xx
Required tools
▪ Phillips screwdriver
▪ Allen key, size 1.5
▪ Open-ended wrench, size 7
▪ Open-ended wrench, size 11
▪ Open-ended wrench, size 14
3.17.1.1
3.17.1.1 Removing the Manometer (Dispenser)
Removing the Manometer (Dispenser)
► Remove the right side cover (see "3.8.1 Removing
the Right Side Cover" [ ➙ 21])
► Carefully place the glue feeder down on its right side.
► Remove the marked Phillips screw.