SPF维修.pdf - 第121页
SPF 6.6 P783 Jumper Setting List SERVICE MANUAL 6.6−6 D54SEC−85−040−B0 PMC (P337N) SA−M00223 2/3 Jumper setting No. Contents ON OFF Setti ngs JP6 Optical loop transmission error interrupt ON Effective OFF Ineffective OFF…

6.6 P783 Jumper Setting List
SERVICE MANUAL
SPF
6.6−5
D54SEC−85−040−B0
PMC (P337N) SA−M00223 1/3
Jumper setting
No. Contents ON OFF
Setti
ngs
JP
4−0
INT0 OFF
JP
4−1
INT1 OFF
JP
4−2
INT2 OFF
JP
4−3
MMC
interrupt
level
INT3 OFF
JP
4−4
MMC
i
n
t
errup
t
l
eve
l
INT4 OFF
JP
4−5
INT5 OFF
JP
4−6
INT6 ON
JP
4−7
INT7 OFF

SPF
6.6 P783 Jumper Setting List
SERVICE MANUAL
6.6−6
D54SEC−85−040−B0
PMC (P337N) SA−M00223 2/3
Jumper setting
No. Contents ON OFF
Setti
ngs
JP6
Optical loop
transmission error
interrupt
ON Effective OFF Ineffective OFF
JP7
Optical loop wire
breaking error interrupt
ON Effective OFF Ineffective OFF
JP13 Watchdog timer ON Ineffective OFF Effective OFF
Dip switch setting
DSW No. No. Contents
Standard
settings
Specifications
1 OFF ADR19
2 ON ADR18
8
3 ON ADR17
8
DSW
1
4
2 port
RAM
upper
address
to
MMC
ON ADR16
DSW
1
5
2
−por
t
RAM
upper a
dd
ress
t
o
MMC
OFF ADR15
6 OFF ADR14
C
7 ON ADR13
C
8 ON ADR12
1
1 axis divided frequency setting
(ON : 1/10 divided frequency,
OFF : 1/1 divided frequency)
ON
1/10 divided
frequency
2
1 axis pulse / direction setting
(ON : pulse / pulse output,
OFF : pulse /direction output)
OFF
Pulse / direction
output
3
2 axis divided frequency setting
(ON : 1/10 divided frequency,
OFF : 1/1 divided frequency)
ON
1/10 divided
frequency
DSW
2
4
2 axis pulse / direction setting
(ON : pulse / pulse output,
OFF : pulse /direction output)
OFF
Pulse / direction
output
DSW
2
5
3 axis divided frequency setting
(ON : 1/10 divided frequency,
OFF : 1/1 divided frequency)
ON
1/10 divided
frequency
6
3 axis pulse / direction setting
(ON : pulse / pulse output,
OFF : pulse /direction output)
OFF
Pulse / direction
output
7
4 axis divided frequency setting
(ON : 1/10 divided frequency,
OFF : 1/1 divided frequency)
ON
1/10 divided
frequency
8
4 axis pulse / direction setting
(ON : pulse / pulse output,
OFF : pulse /direction output)
OFF
Pulse / direction
output

6.6 P783 Jumper Setting List
SERVICE MANUAL
SPF
6.6−7
D54SEC−85−040−B0
PMC (P337N) SA−M00223 3/3
Dip switch setting
DSW No. No. Contents
Standard
settings
Specifications
1
5 axis divided frequency setting
(ON : 1/10 divided frequency,
OFF : 1/1 divided frequency)
ON
1/10 divided
frequency
2
5 axis pulse / direction setting
(ON : pulse / pulse output,
OFF : pulse /direction output)
OFF
Pulse / direction
output
DSW 3
3
6 axis divided frequency setting
(ON : 1/10 divided frequency,
OFF : 1/1 divided frequency)
ON
1/10 divided
frequency
4
6 axis pulse / direction setting
(ON : pulse / pulse output,
OFF : pulse /direction output)
OFF
Pulse / direction
output
5 Not used OFF
6 Not used OFF
7 Not used OFF
8 Not used OFF