SPF维修.pdf - 第53页

SPF 4.1 Adjustment Check List SERVICE MANUAL 4.1−8 D54SEC−83−010−B0 = MEMO =

100%1 / 160
4.1 Adjustment Check List
SERVICE MANUAL
SPF
4.1−7
D54SEC−83−010−B0
No.
Refere
nce
CheckAdjustment Item
SST
NC board optical
CY
10
to
39
m
W
NC
board
optical
loop 1
CX
10
t
o
39
m
W
1
1
Optical loop
light
ST
1
1
li
g
ht
intensity
SQ
NC board optical
SY
10
to
39
m
W
NC
board
optical
loop 2
SCX
10
t
o
39
m
W
SCR
SPF
4.1 Adjustment Check List
SERVICE MANUAL
4.1−8
D54SEC−83−010−B0
= MEMO =
4.2 Lower Section Unit : Others
SERVICE MANUAL
SPF
4.2−1
D54SEC−W4−600−B0
4.2 Lower Section Unit : Others
D54SEC−W4−600−B0
Sentence No.
4.2.1 SY Axis (Stage Y Axis) Motor Replacement
Unit No. 1080804200
SY Axis (Stage Y Axis) Motor
Replacement
4.2.4 SY Axis (Stage Y Axis)
Origin Adjustment
SY axis motor replacement
1. Turn the power [ON] and return to origin.
2. Turn the power [OFF].
3. Disconnect the motor connectors.
4. Loosen the coupling bolt on the motor side.
5. Remove the motor bolts (3 pcs.) and remove
the motor from the motor bracket.
6. Replace the motor.
7. Tighten the motor bolts and coupling bolt.
8. Connect the motor connectors.
Stage Y axis motor
Coupling
Motor bolt
Stage Y axis motor