2.1 Installation Procedure SERVICE MANUAL SPF 2.1−7 D54SEC−1 1−040−C0 2.1.6 Pr ec i si o n, Pe r fo r ma n ce Op e ra tio n Ch ec k / Ma n ua l Operation Main control panel operation check 1. Check an indication at norma…

100%1 / 160
SPF
2.1 Installation Procedure
SERVICE MANUAL
2.1−6
D54SEC−11−040−C0
1 block switch operation check
1. Open the front door and check the safety stop.
2. Select “START” on the main control panel and check if 1 block operation can be continued.
=HINT=
When checking (+), (−) limits operation (NC AXIS JOG movement), move the stage manually.
Return to origin and operate in NC AXIS JOG.
(+), (−) limit operation check
1. Check the machine is at origin.
=REFERENCE=
Refer to ’Operation Manual / Origin Return’.
2. Select ’NC AXIS JOG’ and check each axis (+) and (−) limits.
=CHECK=
Be sure to move the stage manually, and return to origin and then operate in NC AXIS JOG.
Emergency switch operation check
1. Insure that the power supply turns [OFF] when any of the emergency switches in 2 places on the
machine front and in 2 places on the machine rear are turned [ON].
2.1 Installation Procedure
SERVICE MANUAL
SPF
2.1−7
D54SEC−11−040−C0
2.1.6 Precision, Performance Operation Check / Manual
Operation
Main control panel operation check
1. Check an indication at normal of monitor screen.
2. Check input at normal of basic parameter and basic data.
3. Check the operation after returning to origin with selecting “MANU” from the main control panel.
Sub control panel operation check
1. Check that the corresponding operation is performed when each sub control panel switch is turned
[ON] and [OFF] and that the light on the switch turns [ON] and [OFF].
=REMARKS=
Sudden movement occurs when selected switches are operated, so keep hands out of the
machine.
Cleaner operation check
1. Check the sensor of solvent.
=CHECK=
Make sure that the sensor of solvent is set to dark [ON].
Automatic width control operation check
1. Check the origin return operation.
2. Input data and check the operation.
=REFERENCE=
Refer to ’Maintenance Manual / MAINTENANCE GUIDE / Stage Automatic Width Controls Motor
Replacement (Option)’, ’Stage Automatic Width Control Origin Adjustment (Option)’, ’Stage
Automatic Width Control Limit Adjustment (Option)’, ’Positioning Unit Auto Width Control Motor
Replacement and Origin Adjustment (Option)’, ’Loader and Unloader Automatic Width Control
Origin Adjustment (Option)’, ’Loader and Unloader Automatic Width Control Limit Adjustment
(Option)’.
Stage precision check
1. Check the height of the stage, stage rail and screen holder.
=REFERENCE=
Referto’MAINTENANCEGUIDE(MECHANICAL)/STAxis(StageUp/DownAxis)Origin
Adjustment’.
2. Check the rail guide parallelism.
=REFERENCE=
Refer to ’Maintenance Manual / MAINTENANCE GUIDE / Fixed Rail Guide Parallelism
Adjustment’.
3. Check the rail guide coplanarity.
=REFERENCE=
Refer to ’Maintenance Manual / MAINTENANCE GUIDE / Fixed and Movable Rail Guides
Coplanarity Adjustment’.
4. Check the support plate coplanarity.
=REFERENCE=
Referto’MAINTENANCEGUIDE(MECHANICAL)/SupportPlateCoplanarityAdjustment.
SPF
2.1 Installation Procedure
SERVICE MANUAL
2.1−8
D54SEC−11−040−C0
PCB setting
1. Set up transfer rail . positioning pin (positioning lever) according to the PCB size.
2. Input the NC program data.
=CHECK=
Input offset data into NC program without fail.
3. Check screen calibration data operation.
=REFERENCE=
Refer to ’Operating Instructions Programming Manual / Creating the NC Program’.
2.1.7 Precision and Performance Check in Semi Auto Operation
Main control panel operation check in semi automatic mode
1. Check PCB automatic transfer operation (minimum 10 times).
=REFERENCE=
Refer to ’Operation Manual / Semi−automatic Operation’.
2. Check precision in automatic examination mode.
=REFERENCE=
Refer to ’Operation Manual / Positioning Slippage Check’.
3. Check cleaner operation.
=REFERENCE=
Refer to ’Operation Manual /Semi−automatic Operation’.
4. Operate in aging mode for a minimum of 2 hours.
· Check the aging program.
· Select ’NO’ for ’PCB Conv’.
· Select “SEMI” ® “CONT” from the main control panel.
· Select “F1” (AGING) from the main control panel.
· Select “F1” (START) from the main control panel.
=CHECK=
Be sure to select ’YES’ for ’PCB Conv’ after completing above procedures.
5. Check machine level and adjust again.
6. Check wave form of NC gain.
=REFERENCE=
RefertoMAINTENANCEGUIDE(CONTROLS)/ACServoGainAdjustmentinthismanual.