SPF维修.pdf - 第136页

6.7 Secret Screen Service Functions (CONFIDENTIAL) SERVICE MANUAL SPF 6.7−5 D54SEC−85−080−A0 R COMMAND · This is a designation of whether the R command is outputted to the host computer or not. YES : The R command is out…

100%1 / 160
SPF
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
6.7−4
D54SEC−85−080−A0
6.7.3 System Parameter Setting
SELECT ITEM USING KEYS AND PRESS .
2400 9600 19200
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6
F7 F8
[SYSTEM PARAMETER SETTING]
EXIT
R
DATA TYPE
YES
LANGUAGE
CHECKSUM
ETX
NO
YES
4800
JPN
CR
YES
NO
NO
S
3
2
C
2
END COMMAND
LAN
R COMMAND
TIME OUT
MOMENTARY
BAUD RATE
INC
ABS
ENG
NOYES
YES
NO
¯ ¬ ®
ENTER
Figure 6.7−4−System parameter setting screen
Parameter explanation
DATA TYPE
· This is a designation of which data type is used on the display upon the selection.
ABS : The absolute type is used.
INC : The relative type is used.
LANGUAGE
· This is a designation of which language is used on the display upon the selection.
JPN : Japanese is used.
ENG : English is used.
LAN
· This is a designation of whether LAN is used for the communications or not.
YES : LAN is used for communication.
NO : LAN is not used for communication.
CHECKSUM
· This is a designation of whether the checksum of the transferred data is executed or not.
YES : A checksum of the transferred data is executed.
NO : A checksum of the transferred data is not executed. (The error does not
indicate when some troubles are occurred in transferring the data.)
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−5
D54SEC−85−080−A0
R COMMAND
· This is a designation of whether the R command is outputted to the host computer or not.
YES : The R command is output to the host.
NO : The R command is not output to the host.
MOMENTARY
· Select whether duplicate M, T, X, or Y commands are omitted when the C1 command outputs NC data to
the host.
YES : The M, T, X and Y commands in each block are omitted if they are the same.
NO : The M, T, X and Y commands in each block are not omitted even if they are the same.
TIME OUT
· This is a designation of whether the time out is performed or not.
YES : A time out is not performed.
NO : A time out is performed.
END COMMAND
· This is a designation of whether ETX or CR is used as the message end command.
ETX: ETX becomes the message end command.
CR : CR becomes the message end command.
BAUD RATE
· This is a designation of the data transmission speed.
2400 : The data transmission speed is 2400 [bps].
4800 : The data transmission speed is 4800 [bps].
9600 : The data transmission speed is 9600 [bps].
19200 : The data transmission speed is 19200 [bps].
SPF
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
6.7−6
D54SEC−85−080−A0
6.7.4 SC Timer
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>> XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6
F7 F8
[SC TIMER]
EXIT
INITIAL
PREVIOUS
PAGE
NEXT
PAGE
0.30
1.00
0.50
10.00
15.00
15.00
0.20
0.20
0.20
0.50
0.20
0.20
0.20
0.00
0.20
0.20
0.10
0.50
0.50
10.00
0.01
0.03
0.20
0.20
0.20
0.50
0.50
1.00
0.20
0.10
0.20
0.20
1.00
0.50
10.00
0.03
0.60
0.20
0.20
0.20
TM02
TM08
TM14
TM20
TM26
TM32
TM38
TM44
TM01
TM07
TM13
TM19
TM25
TM31
TM37
TM43
TM03
TM09
TM15
TM21
TM27
TM33
TM39
TM45
TM04
TM10
TM16
TM22
TM28
TM34
TM40
TM46
0.50
0.05
10.00
99.00
6.00
0.03
0.20
0.20
TM06
TM12
TM18
TM24
TM30
TM36
TM42
TM48
TM05
TM11
TM17
TM23
TM29
TM35
TM41
TM47
Figure 6.7−5−SC timer screen
Parameter explanation
SC timer
· This is a setting of SC timer.
F1 : The setting is initialized.
F6 : Return to previous page.
F7 : Go to next page.
F8 : Setting is completed.
=REFERENCE=
Referto’SCTimerTable’.