SPF维修.pdf - 第84页
4.7 Cleaner and Screen SERVICE MANUAL SPF 4.7−1 D54MEC−W1−K00−A0 4.7 Cleaner and Screen D54MEC−W1−K00−A0 Sentence No. 4.7.1 Cleaner Head Height Adjustment Unit No. Cleaner Head Height Adjustment =Preparation= 1 . Cleane …

SPF
4.6 Others
SERVICE MANUAL
4.6−2
D54SEC−W0−900−A0
9. Check the limit sensors.
Ascend
prohibition
Valid stroke
Cleaning area (579
)
80±1
Area sensor
Ascend prohibition
−798.5±1
−780
0
−2
−744±1
−165±1
0
−2
Origin
−1
+1
0
−2
Stroke related diagram

4.7 Cleaner and Screen
SERVICE MANUAL
SPF
4.7−1
D54MEC−W1−K00−A0
4.7 Cleaner and Screen
D54MEC−W1−K00−A0
Sentence No.
4.7.1 Cleaner Head Height Adjustment
Unit No.
Cleaner Head Height Adjustment
=Preparation=
1.Cleanerheadheightadjustmentjig
2. Thickness gauge
Cleaner head height adjustment
1. Turn the power [ON] and return to origin.
2. Set the cleaner head height adjustment jig to the
screen holder.
3. Turn “CLEANER UP” on the sub control panel
[ON].
4. Check that there is no clearance between the
cleaner head height adjustment jig and the cleaner
squeegee visually.
5. Check the clearance between the screen holder
and the cleaner head height adjustment jig with the
thickness gauge.
=Specification=
Height (Clearance)
DRY cleaner : 0.3 ±0.1mm
WET / Vacuum cleaner : 0 to +0.1mm
6. Check the clearance between the vacuum nozzle
and screen holder for the wet / vacuum cleaner.
=Specification=
Height (Clearance)
WET / Vacuum cleaner : −0.3 to −0.5mm
7. If not within the specification, loosen the stopper of
the free−mount cylinder to adjust the clearance.
8. Check the clearance again.
Squeegee plate
Stopper
9mm
Free−mount
cylinder
Cleaner head height
adjustment jig
Thickness gauge
A
DRY : 0.3 ± 0.1mm
WET / Vacuum : 0 to
+0.1mm
Screen holder
Cleaner
squeegee
No
clearance
Cleaner head
height adjustment
jig
Cleaner squeegee
Screen holder
Vacuum nozzle
Cleaner squeegee
−0.3 to −0.5mm
View from A : Vacuum nozzle height
Squeegee height
(DRY, WET / Vacuum)

SPF
4.7 Cleaner and Screen
SERVICE MANUAL
4.7−2
D54MEC−W1−K00−A0
= MEMO =