SPF维修.pdf - 第140页

6.7 Secret Screen Service Functions (CONFIDENTIAL) SERVICE MANUAL SPF 6.7−9 D54SEC−85−080−A0 6.7.6 Optional Switch Setting MANUAL : 1BLOCK <<MACHINE INITIAL SETTING>> XXXX−XX−XX XX:XX F1 F2 F3 F4 F5 F6 F7 F8 …

100%1 / 160
SPF
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
6.7−8
D54SEC−85−080−A0
6.7.5 Driver Gain Setting
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6
F7 F8
[DRIVER GAIN SETTING]
EXIT
INITIAL
POSITION FEEDBACK 1st : 0 to 255 2nd : 0 to 255
CX
CY
ST
SST
SCR
SCX
SY
SQ
POSITION FEEDB.
FEED
FORWARD
SPEED FEEDBACK
9
8
28
12
5
4
8
10
20
13
28
9
3
4
10
9
INTEGRAL OF SPD
0
0
0
0
0
0
0
0
20
20
21
20
20
5
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
CHANGE
TIMING
1st 2nd
1st 2nd
1st 2nd
DATA
TRANSFER
9
8
28
12
4
3
8
10
20
13
28
9
2
3
4
9
Figure 6.7−7−Driver gain setting screen
Parameter explanation
· This is a designation of setting the driver gain.
F1 : Transfer the data.
F2 : All driver gain setting are initialized.
F8 : Setting is completed.
=REFERENCE=
Referto’MAINTENANCEGUIDE(CONTROLS)/ACServoGainAdjustmentinthismanual.
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−9
D54SEC−85−080−A0
6.7.6 Optional Switch Setting
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6
F7 F8
[SETS OPTION SWITCH]
EXIT
DISPLAY : INVALID VALID
SC SW
OPTION SW
7654 3210
0000 0000
0000 0000
0000 0000
0000 0000
COMMENT
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1
2
3
OPTION PARAMETER
1
2
3
4
5
6
7
8
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Figure 6.7−8−Optional switch setting screen
Parameter explanation
· This is a designation of setting the optional switch.
· The values in the left side line of option parameter designate the offset values of electric air pressure
regulator and the values in the right side line designate the tilt values of electric air pressure regulator.
Option parameter 1 : Compressed cylinder
Option parameter 2 : Self−weight cancel cylinder
F8 : Setting is completed.
SPF
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
6.7−10
D54SEC−85−080−A0
6.7.7 Machine Parameter Setting
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX : XX
F1
F2 F3 F4 F5 F6
F7 F8
[SETS MACHINE PARA]
EXIT
PREVIOUS
PAGE
NEXT
PAGE
REGULATOR 1
2
3
OFFSET TILT
−1.784 2.033
1.818 2.037
0.000 0.000
W−BALANCE INIT. PRESS
STEP PRESS
BALANCE CYLIN. PRESS
LOAD CYLIN. NON PRESS
0.100
S1 0.002 S2 0.001
UP 0.000 DW 0.000
0.012
EP REGULATOR PARA.
Figure 6.7−9−Machine parameter setting screen 1
Parameter explanation
· This is a designation of setting the machine parameter.
F6 : Return to previous page.