SPF维修.pdf - 第133页
SPF 6.7 Secret Screen Service Functions (CONFIDENTIAL) SERVICE MANUAL 6.7−2 D54SEC−85−080−A0 MANUAL : 1BLOCK <<MACHINE INITIAL SETTING>> XXXX−XX−XX XX:XX F1 F2 F3 F4 F5 F6 F7 F8 [MENU] APPROV EXIT SELECT FUNC…

6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−1
D54SEC−85−080−A0
6.7 Secret Screen Service Functions (CONFIDENTIAL)
D54SEC−85−080−A0
Sentence No.
6.7.1 How to Access the Secret Screen
1. Turn the power [ON].
2. Select “MANU” ®“REQUEST” ® “F1” (MACHINE INITIAL SETTINGS) ® “F7” ® “SHIFT” ® “S”
® “P” ® “SHIFT” ® “F” from the main control panel.
3. The following ’MENU’ screen is displayed on the monitor screen.
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX : XX
F1
F2 F3 F4 F5 F6
F7 F8
RAM
INITIAL
[MENU]
SYSTEM
PARAM
DRIVER
GAIN SET
OPTION
SWITCH
EXIT
SELECT FUNCTION USING F KEYS.
F 1 INITIALIZES RAM AREA
F2
SETS SYSTEM PARAMETER (RS−232C SETTING, SOFT SW)
F3
SETS SC TIMER
F4
SETS DRIVER GAIN
F5
SETS OPTION SWITCHES
SC TIMER
SET
F6
SETS MACHINE PARAMETERS
MACHIN
PARAM
MORE
FUNCTION
Figure 6.7−1−Menu screen
Parameter explanation
· This is a designation of which function keys to execute upon the selection.
F1 : RAM area initialization
F2 : System parameter setting
F3 : SC timer setting
F4 : Driver gain setting
F5 : Optional switch setting
F6 : Machine parameter setting
F7 : Go to next menu.
F8 : Setting is completed.

SPF
6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
6.7−2
D54SEC−85−080−A0
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6
F7 F8
[MENU]
APPROV
EXIT
SELECT FUNCTION USING F KEYS.
F 1 SETS WIDTH INITIAL DATA
APPROVING
F 4 RECOGNITION SERVICE
F5
MORE
FUNCTION
WIDTH
DATA
RECOG
SERVICE
Figure 6.7−2−Menu screen
Parameter explanation
· This is a designation of which function keys to execute upon the selection.
F1 : Width initial data setting
F4 : Carry out recognition service.
F5 : Carry out certification.
F7 : Go to next menu.
F8 : Setting is completed.

6.7 Secret Screen Service Functions (CONFIDENTIAL)
SERVICE MANUAL
SPF
6.7−3
D54SEC−85−080−A0
6.7.2 RAM Initialization
WILL YOU INITIALIZE? ( : YES : NO )
MANUAL : 1BLOCK
<<MACHINE INITIAL SETTING>>
XXXX−XX−XX XX:XX
F1
F2 F3 F4 F5 F6
F7 F8
YES
[RAM INITIALIZATION]
NO
INITIALIZES ALL RAM AREA.
F1
F2
Figure 6.7−3−RAM initialization screen
Parameter explanation
· This is a designation of whether the initialization on all RAM will be execute or not.
F1 : Yes, initialization will be executed on all RAM area.
F2 : No, initialization will not be executed on all RAM area.