4OM-1626-001_w.pdf - 第134页
4OM-1610 3-3 3. Error IDs and Remedial Procedures : Chap.3 091 1-001 3. Error IDs and Remedial Procedures 3.1 Safety Device Error ID Error Name, Description, Cause, and Remedy 400101 Load Power Shutoff The [emergency sto…

4OM-1610
3-2
2. Error IDs and Controlled Areas : Chap.3
2. Error IDs and Controlled Areas
Basic System of Error IDs
An error ID is expressed 6 digits (In hexadecimal notation) as follows.
Major Classication of "Operation Axis", "Process
Error", and "Teaching Operation".
Error IDs and Controlled Areas
Error ID Operation Axis
02
03
04
05
06
07
08
09
0a
0b
0c
0d
0e
0f
10
11
12
13
14
15
16
17
18
19
20
Error ID Processing Error
40 Safety Device
41 Data
42 Conveyor
45
Recognition Communication
46 PEC Recognition
49 Automatic Setup
4a Head Related
4b Other
50 Handling Error
51 Automatic Operation Error
60 Automatic Teaching
FE System Error
T4C2
0911-001

4OM-1610
3-3
3. Error IDs and Remedial Procedures : Chap.3
0911-001
3. Error IDs and Remedial Procedures
3.1 Safety Device
Error ID Error Name, Description, Cause, and Remedy
400101 Load Power Shutoff
The [emergency stop] switch was pressed. (Please conrm the nozzle has not
fallen when you push the beam by the hand.)
Please switch on a power supply after canceling an emergency stop switch and
screen return to normal display.
400102 Load Power Shutoff
An emergency stop switch is pushed.
Please switch on a power supply after canceling an emergency stop switch and
screen return to normal display.
400301 Zeroing Error.
Abnormality was found in processing zeroing operation.
Please perform zeroing.
400401 Interlock Error
The [emergency stop] switch was pressed. (Please conrm the nozzle has not
fallen when you push the beam by the hand.)
Please switch on a power supply after canceling an emergency stop switch and
screen return to normal display.
400402 Interlock Error
The safety cover opened. [K4]
Please shut a safety cover and push the [POWER ON] button.
400403 Interlock Error
The main circuit of the XY Beam was broken. [K**]
-----
400404 Interlock Error
Head (Rear) nozzle descent was detected. [A-B****]
Please perform a zeroing.
400405 Interlock Error
Head (Front) nozzle descent was detected. [B-B****]
Please perform a zeroing.
400406 Interlock Error
Head (Rear) descent was detected. [A-B****]
Please perform a zeroing.
400407 Interlock Error
Head (Front) descent was detected. [B-B****]
Please perform a zeroing.
400408 Interlock Error
A pickup-failed component (Rear) was detected. [DA-B****]
1.Open the cover.
2.Conrm suppressor, Disengaged Latch and remove the devices.
3.Close the cover and Lock it.

4OM-1610
3-4
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
400409 Interlock Error
A pickup-failed component (Front) was detected. [DB-B****]
1.Open the cover.
2.Conrm suppressor, Disengaged Latch and remove the devices.
3.Close the cover and Lock it.
40040A Interlock Error
The feeder opening sensor (Rear) was shaded. [B****]
Please remove the factor which is shading the feeder opening sensor (rear), and
carry out zero return.
40040B Interlock Error
The feeder opening sensor (Front) was shaded. [B****]
Please remove the factor which is shading the feeder opening sensor (front), and
carry out zero return.
40040C Interlock Error
Disengaged Latch(Rear) was detected.
1.Open the cover.
2.Conrm suppressor, Disengaged Latch and remove the devices.
3.Close the cover and Lock it.
40040D Interlock Error
Disengaged Latch(Front) was detected.
1.Open the cover.
2.Conrm suppressor, Disengaged Latch and remove the devices.
3.Close the cover and Lock it.
40040E Interlock Error
The safety cover lock was released.
Close the safety cover and lock it.
40040F Interlock Error
Head (Rear) interlock was detected.
Please perform a zeroing.
400410 Interlock Error
Head (Front) interlock was detected.
Please perform a zeroing.
400411 Interlock Error
Air pressure down was detected.
Check air pipe came off or bend, air compressor.
400412 Interlock Error
Circuit breaker of Vacuum pomp was tripped.
Check vacuum pump and wiring.
400413 Interlock Error
Circuit breaker of XY Beam (Rear) was tripped.
Check servo amplier and cables.
400414 Interlock Error
Circuit breaker of XY Beam (Front) was tripped.
Check servo amplier and cables.
400415 Interlock Error
Over squeeze1 detected (Rear)[B05]
-----