4OM-1626-001_w.pdf - 第156页

4OM-1610 3-25 3. Error IDs and Remedial Procedures : Chap.3 091 1-001 3.2 Data Error ID Error Name, Description, Cause, and Remedy 410301 Pattern Program Error Steps in converted pattern program is more ----- 410302 Patt…

100%1 / 251
4OM-1610
3-24
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
405601 Shut-off safety relay of Elevator(Lower) (Front)
Cut off safety relay of lower elevator (Front).
Conrm the main circuit and safety door.
405701 Shut-off safety relay of Elevator(Upper) (Front)
Cut off safety relay of upper elevator (Front).
Conrm the main circuit and safety door.
405801 Released Elevator unit clamp(Front)
Released elevator unit clamp(Front)[B15426, B15428]
Conrm the Elevator Unit Clamp Sensor(B15426, B15428)
405901 Detecting pickup miss cmpnt of Tray Feeder Cart (Front)
Pickup miss components was detected(Front). [B15412]
1,Open the cover.
2.Conrm suppressor, Disengaged Latch and remove the devices.
3.Close the cover and Lock it.
405A01 Detecting Feeder Disengaged Latch of Tray Feeder Cart(Front)
Feeder Disengaged Latch is detected [B15412]
1.Open the cover.
2.Conrm suppressor, Disengaged Latch and remove the devices.
3.Close the cover and Lock it.
407001 Detecting Head(Rear) nozzle descending
Invalid detection of head(Rear) nozzle descending
Please perform a zeroing.
407101 Detecting Head(Front) nozzle descending
Invalid detection of head(Front) nozzle descending
Please perform a zeroing.
407201 Path Line detect(Rear)
Invalid detection of Path line(Rear)
Please perform a zeroing.
407301 Path Line detect(Front)
Invalid detection of Path line(Front)
Please perform a zeroing.
T4C3
0911-001
4OM-1610
3-25
3. Error IDs and Remedial Procedures : Chap.3
0911-001
3.2 Data
Error ID Error Name, Description, Cause, and Remedy
410301 Pattern Program Error
Steps in converted pattern program is more
-----
410302 Pattern Program Error
There are Errors in converted pattern program(PCB recog steps Error.)
-----
410303 Pattern Program Error
The converted pattern program is not exist, the data is damaged.
-----
410304 Pattern Program Error
The error is found in the adsorption nozzle number of the conversion pattern
program.
-----
410305 Pattern Program Error
The error is found in the order of adsorption of the conversion system pattern
program.
-----
410306 Pattern Program Error
The error is found in the nozzle candidate number of the conversion pattern
program.
-----
410307 Pattern Program Error
The error is found in the adsorption lane number of the conversion pattern
program.
-----
410401 Data Error
The components library does not exist. Or, data is in loss.
-----
410402 Data Error
Data relating to nozzle does not exist. Or, data is in loss.
-----
410701 Program Error
It was a error setting of the sequence data was found.
-----
T4C4
4OM-1610
3-26
3. Error IDs and Remedial Procedures : Chap.3
0911-001
3.3 Conveyor
Error ID Error Name, Description, Cause, and Remedy
420101 Backup (L) Axis Error.
The movement of Backup(L) Axis was not completed within predetermined time.
Backup axis is unable to do upward movement and downward movement. The
problem is for Motor, Driver, Sensor Error or wiring Error.
Please check the motor, sensor on Machine check screen.
420102 Backup (L) Axis Error.
Driver Alarm on Backup(L) Axis
Check out reset Method of detailed Sub-system error counts of Alarm.
420103 Backup (L) Axis Error.
Error in calculating data of Backup(L) Axis
Please check the following data
1. Machine Offset/Backup Pin(Up & Down)
2. Pattern program/P.C.B. information/P.C.B. size/thickness
3. Control/Common/PRE-PLACED CMPNT THKNS/Bottom of P.C.B.
420104 Backup (L) Axis Error.
Time-over of zeroing of Backup(L) Axis
Check out the dirt, error, disconnection of sensor. If there is no problem with
sensor, the problem could be with motor wire/single error.
420105 Backup (L) Axis Error.
Time Over of the upward movement of stopper(L)
1.Check out the P.C.B. between stopper and conveyor
2. Error in Up/Down detection sensor. Check out the sensor input
3.Disconnection, Error of Movement output. Please check Stopper by manual
movement if sensor input is proper.
4. Please set speed again by adjusting speed control when stopper is slow.
420106 Backup (L) Axis Error.
Time-over of downward Stopper(L)
1.Up/Down Detect Sensor is out of order. Please check Sensor input
2. Disconnection/Error of output. Please check Stopper by manual movement if
sensor input is proper.
3. Please set speed again by adjusting speed control when stopper is slow.
420107 Backup (L) Axis Error.
Communication Error of the command of P.C.B. positioning(Backup)
Error in Motor Driver, Communications trouble(AE-LINK), Error in Communication
P.C.B.(API). Check out the wiring of Communication line, power supply line.
420108 Backup (L) Axis Error.
Backup Pin/Jig under the conveyor belt is detected.
Check out the interference in Belt on Backup Base does not exist.
420110 Backup(L) Error
Not ready for System setup of Backup(L) axis
Driver has not completed the parameter setup yet. It is a situation in which
a correct setup has not been received by Communication Error. Check the