4OM-1626-001_w.pdf - 第185页
4OM-1610 3-54 3. Error IDs and Remedial Procedures : Chap.3 091 1-001 3.5 PEC Recognition Error ID Error Name, Description, Cause, and Remedy 460101 P .E.C. Inspection P .E.C. Mark #1 (Global) ----- 460102 P .E.C. Inspec…

4OM-1610
3-53
3. Error IDs and Remedial Procedures : Chap.3
0911-001
3.4 Recognition Communication
Error ID Error Name, Description, Cause, and Remedy
450101 Recog. Comm. Error
Recognition Error Code.
-----
450102 Recog. Comm. Error
Time-Out Error
-----
450103 Recog. Comm. Error
GUI starting failure.
-----
T4C6

4OM-1610
3-54
3. Error IDs and Remedial Procedures : Chap.3
0911-001
3.5 PEC Recognition
Error ID Error Name, Description, Cause, and Remedy
460101 P.E.C. Inspection
P.E.C. Mark #1 (Global)
-----
460102 P.E.C. Inspection
P.E.C. Mark #2 (Global)
-----
460103 P.E.C. Inspection
P.E.C. Mark #3 (Global)
-----
460104 P.E.C. Inspection
P.E.C. Mark #1 (Image)
-----
460105 P.E.C. Inspection
P.E.C. Mark #2 (Image)
-----
460106 P.E.C. Inspection
P.E.C. Mark #3 (Image)
-----
460107 P.E.C. Inspection
P.E.C. Mark #1 (Local)
-----
460108 P.E.C. Inspection
P.E.C. Mark #2 (Local)
-----
460109 P.E.C. Inspection
P.E.C. Mark #3 (Local)
-----
46010a P.E.C. Inspection
Land P.E.C. Mark #1
-----
46010b P.E.C. Inspection
Land P.E.C. Mark #2
-----
46010c P.E.C. Inspection
Land P.E.C. Mark #3
-----
46010d P.E.C. Inspection
Failed in P.E.C. Recognition
Please perform to the following
1. Repeat P.C.B. positioning
2. Conrm whether the Mark position of P.C.B. Recognition is correct.
T4C7

4OM-1610
3-55
3. Error IDs and Remedial Procedures : Chap.3
0911-001
3.6 Automatic Adjustment
Error ID Error Name, Description, Cause, and Remedy
490603 Conveyor Width Automatic Adjustment
PCB exists on the L conveyor.
-----
490604 Conveyor Width Automatic Adjustment
PCB exists on the R conveyor.
-----
490617 Conveyor Width Automatic Adjustment
Software limit
-----
490690 Conveyor Width Automatic Adjustment
Auto Setup Error(Others).
-----
490701 Nozzle set up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702 Nozzle set up
Motor Error Detection.
-----
490703 Nozzle set up
Nozzle Stocker Shutter open/close failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490704 Nozzle set up
The up/down movement of Nozzle Stocker failed.
Please conrm whether Upper/Lower Cylinder has no error.
490705 Nozzle set up
Nozzle placing was not found in the stocker.
Check whether there is any difference in stocker arrangement data and real
arrangement.
490707 Nozzle set up
There is no free space for nozzle storing. Please conrm the arrangement data.
Please conrm the Stocker arrangement data.
490708 Nozzle set up
There are neither a free space nor a nozzle for nozzle exchange.
Please set up an insufcient nozzle in Nozzle stocker.
490709 Nozzle set up
Nozzle exchange abnormal data was found.
Please conrm the nozzle arrangement and the Stocker arrangement data.
49070a Nozzle set up
Nozzle stocker position teaching failed.
Please teach the Nozzle stocker position again on the instruction screen.
49070c Nozzle set up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen,
and conrm there is no unexpected value.