4OM-1626-001_w.pdf - 第179页

4OM-1610 3-48 3. Error IDs and Remedial Procedures : Chap.3 091 1-001 Error ID Error Name, Description, Cause, and Remedy 426102 Detection of positioning conveyor sensor Decrease sensor of input position was not detected…

100%1 / 251
4OM-1610
3-47
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
425109 Detection of Input conveyor sensor
P.C.B. on Input conveyor was detected
Remove P.C.B. from Conveyor.
42510a Detection of Input conveyor sensor
P.C.B. on Input conveyor was not detected
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
42510b Detection of Input conveyor sensor
2 P.C.B. pieces on conveyor exist.
Remove it if unnecessary P.C.B. exists, when checking P.C.B. on Conveyor.
42510c Detection of Input conveyor sensor
P.C.B. on sensor was detected in the state of not placing P.C.B.
There is a possibility whether P.C.B. is inserted or P.C.B. arrived before detecting
signals.
42510d Detection of Input conveyor sensor
Disengaged P.C.B. of Input conveyor
Possible to driver continuously. Please conrm the state of P.C.B. if it is not
removed purposely
42510e Detection of Input conveyor sensor
P.C.B. was not detected when placement was completed
P.C.B. from Input Machine is not received and sent.
Please conrm whether P.C.B. on Input conveyor is caught.
42510f Detection of Input conveyor sensor
P.C.B. was detected from Input conveyor sensor
P.C.B. is inserted though the mode that could not be inserted.
Please remove the inserted P.C.B..
425110 Detection of Input conveyor sensor
P.C.B. was detected from Input conveyor sensor
P.C.B. is inserted in P-OUT valid mode.
425201 Input conveyor timeout
Placement was not completed within predetermined time.
There is a possibility that P.C.B. is caught, or dropped from Conveyor.
Please check the transition with Input Machine.
425202 Input conveyor timeout
Output was not completed within predetermined time.
There is a possibility that P.C.B. is caught, or dropped from Conveyor.
Please check the above conveyor.
425301 Input conveyor Error
Error in Input conveyor
-----
426101 Detection of positioning conveyor sensor
Decrease sensor of input position was detected before starting.
There is an indenite P.C.B. on Input position decelerating sensor.
Please remove P.C.B..
4OM-1610
3-48
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
426102 Detection of positioning conveyor sensor
Decrease sensor of input position was not detected before starting.
There is no P.C.B. on conveyor.
1. Please put P.C.B. on Sensor
2. There is a possibility of P.C.B. fallen. Please check the width of Conveyor.
426103 Detection of positioning conveyor sensor
Stop sensor of input position was detected before starting.
There is an indenite P.C.B. on Input position stop sensor.
Please remove P.C.B..
426104 Detection of positioning conveyor sensor
Stop sensor of input position was not detected before starting.
There is no P.C.B. on conveyor.
1. Please put P.C.B. on Sensor
2. There is a possibility of P.C.B. fallen. Please check the width of Conveyor.
426105 Detection of positioning conveyor sensor
Decrease sensor of input position was detected after starting.
There is an indenite P.C.B. on Input position decelerating sensor. Please remove
P.C.B..
426106 Detection of positioning conveyor sensor
Decrease sensor of input position was not detected after starting.
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
426107 Detection of positioning conveyor sensor
Stop sensor of input position was detected before starting.
There is an indenite P.C.B. on Input position stop sensor.
Please remove P.C.B..
426108 Detection of positioning conveyor sensor
Stop sensor of input position was not detected before starting.
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
426109 Detection of positioning conveyor sensor
Decrease sensor of output position was detected before starting.
There is an indenite P.C.B. on Output position decelerating sensor.
Please remove P.C.B..
42610a Detection of positioning conveyor sensor
Decrease sensor of output position was not detected before starting.
There is no P.C.B. on conveyor.
1. Please put P.C.B. on Sensor
2. There is a possibility of P.C.B. fallen. Please check the width of Conveyor.
42610b Detection of positioning conveyor sensor
Stop sensor of output position was detected before starting.
There is an indenite P.C.B. on Output position stop sensor.
Please remove P.C.B..
4OM-1610
3-49
3. Error IDs and Remedial Procedures : Chap.3
0911-001
Error ID Error Name, Description, Cause, and Remedy
42610c Detection of positioning conveyor sensor
Stop sensor of output position was not detected before starting.
There is no P.C.B. on conveyor.
1. Please put P.C.B. on Sensor
2. There is a possibility of P.C.B. fallen. Please check the width of Conveyor.
42610d Detection of positioning conveyor sensor
Decrease sensor of output position was detected after starting.
There is an indenite P.C.B. on Output position stop sensor.
Please remove P.C.B..
42610e Detection of positioning conveyor sensor
Decrease sensor of output position was not detected after starting.
-----
42610f Detection of positioning conveyor sensor
Stop sensor of output position was detected before starting.
There is an indenite P.C.B. on Output position stop sensor.
Please remove P.C.B..
426110 Detection of positioning conveyor sensor
Stop sensor of output position was not detected before starting.
Please check whether P.C.B. is detected correctly.
Check whether the sensor doesn’t have Error.
426111 Detection of positioning conveyor sensor
P.C.B. on positioning conveyor was detected
Please remove P.C.B. from positioning conveyor.
426112 Detection of positioning conveyor sensor
NO P.C.B. on positioning conveyor
Conrm whether P.C.B. is not dropping.
Conrm whether Sensor is not broken.
426201 positioning conveyor timeout
Placement for input position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input conveyor to Input
position or is dropped. Please conrm from Input to positioning conveyor.
426202 positioning conveyor timeout
Output from input position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input position to Output or is
dropped.
Please conrm from positioning to Output conveyor.
426203 positioning conveyor timeout
Placement for output position was not completed within predetermined time.
P.C.B. inserted is place in Output position.
There is a possibility of it fallen. Please conrm from Input to Positioning conveyor.
426204 positioning conveyor timeout
Output from output position was not completed within predetermined time.
There is a possibility whether P.C.B. is placed from Input position to Output or is
dropped.
Please conrm from positioning to Output conveyor.