4OM-1626-001_w.pdf - 第248页
4OM-1610 3-1 17 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 604619 T eaching Height of Glass Jig Error in Flowing Quantity ----- 604701 T eaching Height of T raverse …

4OM-1610
3-116
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
60460a Teaching Height of Glass Jig
Time-out of starting HL-axis movement
-----
60460b Teaching Height of Glass Jig
Time-out of starting NL-axis movement
-----
60460c Teaching Height of Glass Jig
Time-out of nishing HL/NL-axis movement
-----
60460d Teaching Height of Glass Jig
Failed in measuring real time of linear measure sensor.
-----
60460e Teaching Height of Glass Jig
Error in measuring Linear measure sensor
-----
60460f Teaching Height of Glass Jig
Flange of Nozzle is not detected within the predetermine range.(Under 0.2mm)
-----
604610 Teaching Height of Glass Jig
Flange of Nozzle is not detected within the predetermine range.(Over 2.5mm)
-----
604611 Teaching Height of Glass Jig
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604612 Teaching Height of Glass Jig
Program Error
-----
604613 Teaching Height of Glass Jig
Offset is 1mm less than the set value.
-----
604614 Teaching Height of Glass Jig
Offset is 1mm more than the set value.
-----
604615 Teaching Height of Glass Jig
The value of Flowmeter is higher than 5.0V.
-----
604616 Teaching Height of Glass Jig
The value of Flowmeter is lower than 4.7V.
-----
604617 Teaching Height of Glass Jig
There is no measured data of Noz 1. It is necessary to measure Noz1
rst.
-----
604618 Teaching Height of Glass Jig
Cannot measure it for XY-coord is not dened.
-----
0911-001

4OM-1610
3-117
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604619 Teaching Height of Glass Jig
Error in Flowing Quantity
-----
604701 Teaching Height of Traverse Chute
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604702 Teaching Height of Traverse Chute
Time-out of [OFF] signal of Linear measure sensor
-----
604703 Teaching Height of Traverse Chute
Error in DD-axis
-----
604704 Teaching Height of Traverse Chute
Error in NS-axis
-----
604705 Teaching Height of Traverse Chute
Error in DD/NS-axis
-----
604706 Teaching Height of Traverse Chute
Time-out of DD/NS-axis
-----
604707 Teaching Height of Traverse Chute
Error in calculating drive wave of HL-axis
-----
604708 Teaching Height of Traverse Chute
Error in calculating drive wave of NL-axis
-----
604709 Teaching Height of Traverse Chute
Time-out of starting HL/NL-axis movement
-----
60470a Teaching Height of Traverse Chute
Time-out of starting HL-axis movement
-----
60470b Teaching Height of Traverse Chute
Time-out of starting NL-axis movement
-----
60470c Teaching Height of Traverse Chute
Time-out of nishing HL/NL-axis movement
-----
60470d Teaching Height of Traverse Chute
Failed in measuring real time of linear measure sensor.
-----
60470e Teaching Height of Traverse Chute
Error in measuring Linear measure sensor
-----
0911-001

4OM-1610
3-118
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
60470f Teaching Height of Traverse Chute
Flange of Nozzle is not detected within the predetermine range.(Under 0.2mm)
-----
604710 Teaching Height of Traverse Chute
Flange of Nozzle is not detected within the predetermine range.(Over 2.5mm)
-----
604711 Teaching Height of Traverse Chute
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604712 Teaching Height of Traverse Chute
Program Error
-----
604713 Teaching Height of Traverse Chute
Offset is 1mm less than the set value.
-----
604714 Teaching Height of Traverse Chute
Offset is 1mm more than the set value.
-----
604715 Teaching Height of Traverse Chute
The value of Flowmeter is higher than 5.0V.
-----
604716 Teaching Height of Traverse Chute
The value of Flowmeter is lower than 4.7V.
-----
604717 Teaching Height of Traverse Chute
There is no measured data of Noz 1. It is necessary to measure Noz1
rst.
-----
604718 Teaching Height of Traverse Chute
Cannot measure it for XY-coord is not dened.
-----
604719 Teaching Height of Traverse Chute
Error in Flowing Quantity
----
T4C13
0911-001