4OM-1626-001_w.pdf - 第239页
4OM-1610 3-108 3. Error IDs and Remedial Procedures : Chap.3 Error ID Error Name, Description, Cause, and Remedy 60410f T eaching Placement-Height Flange of Nozzle is not detected within the predetermine range.(Under 0.2…

4OM-1610
3-107
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604003 Automatic Teaching on producing operation.
Could not recognize the Standard Mark.
-----
604101 Teaching Placement-Height
Error is detected before starting Detection on the Linear Sensor.(There is a
possibility that the Linear measure Sensor is broken , or Odd Noz is placed)
-----
604102 Teaching Placement-Height
Time-out of [OFF] signal of Linear measure sensor
-----
604103 Teaching Placement-Height
Error in DD-axis
-----
604104 Teaching Placement-Height
Error in NS-axis
-----
604105 Teaching Placement-Height
Error in DD/NS-axis
-----
604106 Teaching Placement-Height
Time-out of DD/NS-axis
-----
604107 Teaching Placement-Height
Error in calculating drive wave of HL-axis
-----
604108 Teaching Placement-Height
Error in calculating drive wave of NL-axis
-----
604109 Teaching Placement-Height
Time-out of starting HL/NL-axis movement
-----
60410a Teaching Placement-Height
Time-out of starting HL-axis movement
-----
60410b Teaching Placement-Height
Time-out of starting NL-axis movement
-----
60410c Teaching Placement-Height
Time-out of nishing HL/NL-axis movement
-----
60410d Teaching Placement-Height
Failed in measuring real time of linear measure sensor.
-----
60410e Teaching Placement-Height
Error in measuring Linear measure sensor
-----
0911-001

4OM-1610
3-108
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
60410f Teaching Placement-Height
Flange of Nozzle is not detected within the predetermine range.(Under 0.2mm)
-----
604110 Teaching Placement-Height
Flange of Nozzle is not detected within the predetermine range.(Over 2.5mm)
-----
604111 Teaching Placement-Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604112 Teaching Placement-Height
Program Error
-----
604113 Teaching Placement-Height
Offset is 1mm less than the set value.
-----
604114 Teaching Placement-Height
Offset is 1mm more than the set value.
-----
604115 Teaching Placement-Height
The value of Flowmeter is higher than 5.0V.
-----
604116 Teaching Placement-Height
The value of Flowmeter is lower than 4.7V.
-----
604117 Teaching Placement-Height
There is no measured data of Noz 1. It is necessary to measure Noz1
rst.
-----
604118 Teaching Placement-Height
Cannot measure it for XY-coord is not dened.
-----
604119 Teaching Placement-Height
Error in Flowing Quantity
-----
604201 Chute(For adjustment when shipping up) Teaching Height
Error is detected before starting Detection on Linear Measure Sensor.(There is a
possibility that Linear measure sensor is broken, or Odd Noz is placed.)
-----
604202 Chute(For adjustment when shipping up) Teaching Height
Time-out of [OFF] signal of Linear measure sensor
-----
604203 Chute(For adjustment when shipping up) Teaching Height
Error in DD-axis
-----
604204 Chute(For adjustment when shipping up) Teaching Height
Error in NS-axis
-----
0911-001

4OM-1610
3-109
3. Error IDs and Remedial Procedures : Chap.3
Error ID Error Name, Description, Cause, and Remedy
604205 Chute(For adjustment when shipping up) Teaching Height
Error in DD/NS-axis
-----
604206 Chute(For adjustment when shipping up) Teaching Height
Time-out of DD/NS-axis
-----
604207 Chute(For adjustment when shipping up) Teaching Height
Error in calculating drive wave of HL-axis
-----
604208 Chute(For adjustment when shipping up) Teaching Height
Error in calculating drive wave of NL-axis
-----
604209 Chute(For adjustment when shipping up) Teaching Height
Time-out of starting HL/NL-axis movement
-----
60420a Chute(For adjustment when shipping up) Teaching Height
Time-out of starting HL-axis movement
-----
60420b Chute(For adjustment when shipping up) Teaching Height
Time-out of starting NL-axis movement
-----
60420c Chute(For adjustment when shipping up) Teaching Height
Time-out of nishing HL/NL-axis movement
-----
60420d Chute(For adjustment when shipping up) Teaching Height
Failed in measuring real time of linear measure sensor.
-----
60420e Chute(For adjustment when shipping up) Teaching Height
Error in measuring Linear measure sensor
-----
60420f Chute(For adjustment when shipping up) Teaching Height
Flange of Nozzle is not detected within the predetermine range.(Under 0.2mm)
-----
604210 Chute(For adjustment when shipping up) Teaching Height
Flage of Nozzle is not detected within the predetermine range.(Over 2.5mm)
-----
604211 Chute(For adjustment when shipping up) Teaching Height
The height of Flange of Nozzle is not changed.(Nozzle pressed is not detected.)
-----
604212 Chute(For adjustment when shipping up) Teaching Height
Program Error
-----
604213 Chute(For adjustment when shipping up) Teaching Height
Offset is 1mm less than the set value.
-----
0911-001