FUJI 24 HEAD Replacing ALL syringe_IPS.pdf - 第37页

Edition 2.0 NXT/NXT2 Repair Training T ext H12HS(Q) Hea d FK-9F98-61-0E 7-9 FUJI MACHINE MFG . CO., L TD. 18. Attach the syringe gear to the syringe. Follow the procedure below when using the H12HS θ -axis phase alignmen…

100%1 / 180
Edition 2.0 NXT/NXT2 Repair Training Text
H12HS(Q) Hea
d
FK-9F98-61-0E 7-8 FUJI MACHINE MFG. CO., LTD.
15. Use the push-pull gaugeDPS-5to measure the slide resistance of all the syringes.
Check that the measured value is 0.98 N or less (within 100 g).
16. Attach the spring and bearing to the syringe.
17. Use the H12 syringe pin insertion jig AA1XC0* to insert the pin into the syringe.
Note: the H12 syringe pin insertion jig (AA1XC0*) is also used for the H12S head.
H12 syringe pin in
AA1XC0*
Bearing
Spring
Push-pull gaugeDPS-5
CONFIDENTIAL
SmartechMr.J FSun
Edition 2.0 NXT/NXT2 Repair Training Text
H12HS(Q) Hea
d
FK-9F98-61-0E 7-9 FUJI MACHINE MFG. CO., LTD.
18. Attach the syringe gear to the syringe. Follow the procedure below when using the
H12HSθ-axis phase alignment jig (AA6LH0*).
Note: The PM6637* component of the H12HS θ-axis phase alignment jig (AA6LHO*) is
the same as that used for the H12Sθ-axis phase alignment jig
However, the
jig PM07RA is only for the H12S head.
1 Attach the H12HSθ-axis phase alignment jigPM6637* to the rotary holder.
Note:
The H12HSθ-axis phase alignment jig
PM6637*
is also used as the H12S
head θ-axis phase alignment jig.
2 Attach the H12HSθ-axis phase alignment jig PM07RA*to all the syringes.
Caution: The jig (PM07RA*
should only be used on the H12HS head. It is not for use
on the H12S head.
H12HSθ-axis phase
alignment jig AA6LH0*
PM6637*
PM07RA*
PM6637*
PM07RA*
CONFIDENTIAL
SmartechMr.J FSun
Edition 2.0 NXT/NXT2 Repair Training Text
H12HS(Q) Hea
d
FK-9F98-61-0E 7-10 FUJI MACHINE MFG. CO., LTD.
3 As shown in the following photo, align the cutout section of the jigs attached to the
syringes with the pins on the other jig. Under these conditions the phases of the
syringe, gear and rotary holder are all aligned.
19. When attaching a new syringe gear, the syringe to which the gear should be attached
differs depending on the holder position. Refer to the table on the following page to
prepare an appropriate gear.
Upper gear
(PM04MK*)
Lower gear
(PM4MH*)
(PM053S*)
(PM053T*)
Spring
(PZ3439*)
Upper gear
Spring
Lower gear
CONFIDENTIAL
SmartechMr.J FSun