00196771-01_IM_SSW_705_03_DE_EN.pdf - 第43页
Installation Manual, Station Software Version 705.03 02/2011 Edition The user settings are displayed. Fig. 7-3: Changing activity level → Click the Machine servi ce button and enter the password to c hange into this acti…

Installation Manual, Station Software Version 705.03 02/2011 Edition
Fig. 7-2: Used hardware components
The Machine service activity level is required to execute the Auto-configuration.
→ Click the
icon to call the user settings.
42 of 58

Installation Manual, Station Software Version 705.03 02/2011 Edition
The user settings are displayed.
Fig. 7-3: Changing activity level
→ Click the Machine service button and enter the password to change into this activity level.
43 of 58

Installation Manual, Station Software Version 705.03 02/2011 Edition
As of station software version 705.03 you will have to set, whether the lamp indicators on the placement
machine towers shall be displayed two-colored (green / white) or three-colored (green / white / red) for all
placement machines of the SX-series and DX-series. More information about the two lamp indicator
systems can be found in the version description of the station software, item number 00196770-xx.
Fig. 7-4: Setting lamp indicators
→ Select the desired lamp indicators and click the Accept button.
44 of 58