Test Research, Inc. TR7600 SIII Ser ies User G uide – Cam era Calibr ation 23 2.5 High Re s. Image Offset Calibr ation Note: Generally, this calibration is not required. Please check with TRI FAEs before performing this …

Test Research, Inc.
22 TR7600 SIII Series User Guide – Camera Calibration
3) Locate the center of the cross line at the center of two white square boxes.
Figure 29: Height Calibration Steps
4) Press [Calculate] and some values will change in the calibration dialogue as shown
below.
5) Press [Close].
6) Press [OK] to complete the calibration process.

Test Research, Inc.
TR7600 SIII Series User Guide – Camera Calibration 23
2.5 High Res. Image Offset Calibration
Note: Generally, this calibration is not required. Please check with TRI FAEs before
performing this calibration. Without professional assistance, calibration that failed
may cause issues which are difficult to resolve.
Go to [Utility] [System Calibration] [High Res. Image Offset]
Figure 30: Utility/System Calibration/High Resolution Image Offset
Please follow the procedures below.
1) Click [Scan]
2) Surround the white hole with a frame slightly larger than the hole itself.
3) Click “Start”.
Figure 31: High Resolution Image Offset Calibration Steps

Test Research, Inc.
24 TR7600 SIII Series User Guide – Camera Calibration
4) If the test score is very close to 100, then the calibration is successful. Otherwise, the
calibration is considered fail and user need to repeat the calibration steps from 1) to 3)
until the test score is very close to 100.
Figure 32: High Resolution Image Offset Calibration Steps
5) Click [Close] to complete the calibration.