00193697-01.pdf - 第41页
SIPLACE S oftware Guide SR.504.xx 3 Graphical user interface Issue 01/03 E N 3.3 User interface - views and menus 41 Run options.. . Alt+t 3 This me nu item can be used to switc h the statio n to cycle mo de (after press…

3 Graphical user interface SIPLACE Software Guide SR.504.xx
3.3 User interface - views and menus Issue 01/03 EN
40
Å Click the Software options menu item.
The following window is opened.
3
Fig. 3.3 - 12 "Software options" dialog box (Example HF)
Å Select the tab corresponding to the required machine component and activate/deactivate the
test commands by clicking the corresponding checkboxes.
Å Click Accept to set the software options. The changes take effect with the next printed circuit
board.
NOTE
When the station is rebooted, the software options are reset to their original settings. 3

SIPLACE Software Guide SR.504.xx 3 Graphical user interface
Issue 01/03 EN 3.3 User interface - views and menus
41
Run options... Alt+t 3
This menu item can be used to switch the station to cycle mode (after pressing the stop button)
or to travel at reduced speed. This function can be used to localize errors. 3
Å Click the Run options... menu item or press the key combination ALT+t. The "Run options"
settings box is opened.
Å Check the Cycle mode box to activate cycle mode, or the Reduced speed box to travel at
reduced speed.
NOTE
In cycle mode, you must press the Start button on the machine for every operating step. 3
Video image PA1 > Alt+8 3
In the case of certain actions, it may be necessary to display the camera image of the machine
vision system (vision evaluation unit) on-screen during assembly. 3
Å Click the Video image PA1> menu item or press the key combination ALT+8. The display area
is switched to the MVS camera image in processing area 1.
Å Press the ESC key to restore the display area to the normal view.
Video image PA2 > Alt+9 3
Switch to the MVS camera image in processing area 2. 3
Fine calibration mode... 3
In "Stand alone" control mode, you can use this menu item to load the data of a selected panel
(placement program) from the station computer’s hard disk. 3
Å Please refer to the Fine Calibration User Manual and the online Help system for a detailed
description.
GEM default settings... 3
You use this item to specify the GEM parameters which are used as the default parameters when
the station is switched on. 3
Å Click the GEM default settings... menu item.
The window in which you set the GEM default parameters is now opened.

3 Graphical user interface SIPLACE Software Guide SR.504.xx
3.3 User interface - views and menus Issue 01/03 EN
42
PCB barcode... 3
You use this item to display a dialog box with a list of the barcodes most recently read by the PCB
barcode reader.
This dialog box also informs you if an error occurred while reading the barcode, if the file format
is incorrect or if no data is available. 3
NOTE
You cannot call the "PCB barcode..." menu item unless the PCB barcode reader has been in-
stalled in the machine and has been activated in the machine options. 3
Å Click the PCB barcode... menu item.
The "PCB barcode" dialog box is opened.
3
Fig. 3.3 - 13 "PCB barcode" dialog box (example: only 1 conveyor)
Å Click the Delete list button if you want to delete all the entries in the list.
Å Click the Close button to close the dialog box.
3