00193697-01.pdf - 第48页
3 Graphical user int erface SIPLACE Softw are Guide SR.504.xx 3.4 Flow chart for the main v iew Issue 01/03 EN 48

SIPLACE Software Guide SR.504.xx 3 Graphical user interface
Issue 01/03 EN 3.4 Flow chart for the main view
47
3.4 Flow chart for the main view
3
3
3
Pull-down menus
3
Error information
bar
3
Status indication
and process status
3
Notification about a
specific action to
carry out
3
Information bar
3
Control modes:
Stand alone
SIPLACE Pro
3
Submenu icons with info box:
Main view
Setup
Error
Feeders
Gantry 1, 2
PCB conveyor 2, 1
Teach fiducial
Test component
SITEST
GEM
3
Output conveyor
The output conveyor is empty.
MTC on location 2
Central conveyor
The PCB is supplied.
Input conveyor
The input conveyor is empty.
3
Context-sensitive help system
This also provides a short description of all
displayed operating elements.
3
Help system for errors
Starts a help system displaying possible
causes of the current error along with correc-
tive actions.
3
Error deletion
After the error has been successfully cor-
rected, the currently active error is deleted.
Transport 2
Transport 1
3
Identifies the job or panel of the
right conveyor lane, or of the
single conveyor, and of the left
conveyor lane (dual conveyors
only).
3
Barcode-supported component
refilling
3
PCB barcode is activated.
3
Machine options have been
changed
3
Software options configured
3
Compressed air switch-off
mechanism configured
1234
1 No setup available on the corresponding location
2 Setup available
3 Setup available - at least one empty track error
4 Machine standstill due to track error
3
This display appears during the start-up process of the machine. Only when the
reference run has been completed successfully will the display appear in the form
of a button.
3
Status
The machine is running, or is in its 'ready' state.
Pressing the button:
The machine stops.
3
Status
The machine is placing components; 'stop' is activated. The assembly of the
PCBs located in processing conveyors 1 and 2 or in the central conveyor will be
terminated and the PCBs will be transported to the intermediate or output
conveyor. Subsequently, the machine will stop.
Pressing the button:
The machine continues to run without interruption.
3
Status
Machine is in the stopped state.
Pressing the button:
The machine resumes the placement operation.
3 Graphical user interface SIPLACE Software Guide SR.504.xx
3.4 Flow chart for the main view Issue 01/03 EN
48

SIPLACE Software Guide SR.504.xx 4 Switching the SIPLACE line on and off
Issue 01/03 EN 4.1 Switching on the SIPLACE line
49
4 Switching the SIPLACE line on and
off
This chapter contains information about switching the SIPLACE line on and off. 4
4.1 Switching on the SIPLACE line
4.1.1 Starting the SIPLACE Pro programming system
Å Start SIPLACE Pro from the Windows NT Start menu:
Start --> Programs --> Siemens SIPLACE
or
Å Start SIPLACE Pro
by clicking the icon on your desktop.
The system then connects to SIPLACE Pro Server and opens up the SIPLACE Pro user interface.4
While you are waiting for the system to connect to the SIPLACE Pro Server you will see the fol-
lowing screen. 4