174 9 Calibration of SI PLACE HS-50 (incl. SITES T version 501.xx ) Adjustment Instructions S IPLACE HS-50 9.6 Calibration Collect & P lace Head Noz zle Changer Softwareversion SR.501.xx Edition 12/00 NOTE Th…

Adjustment Instructions SIPLACE HS-50 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx)
Softwareversion SR.501.xx Edition 12/00 9.6 Calibration Collect & Place Head Nozzle Changer
173
&DOLEUDWLRQ&ROOHFW3ODFH+HDG1R]]OH&KDQJHU
&RPSOHWH&DOLEUDWLRQ
Example: Nozzle changer for C&P Head 1, completely supplied with all 5 or 10 magazines.
6,7(67
Å Select "C&P Heads" ==> "C&P Head 1" ==>
"C&P Head nozzle changer" ==> "Complete calibration".
Å Proceed under section "Calibration of the Pick-Up Height". (See section 9.6.3).
NOTE
Make sure that the calibration data for the
PCB camera, the segment offset II (C&P
PCB camera offset) and the machine zero
point have been determined already.
NOTE
A nozzle changer contains 5 magazines
maximum, with 12 nozzle garages each.
For every single C&P Head, 2 nozzle
changers may be installed. During
calibration these will be handled like one
single nozzle changer with 10 magazines.
NOTE
The function "Complete calibration" is
used, if the nozzle changer is completely
loaded with all 5 or 10 magazines.
All 12 nozzles must be on the C&P Head.
With the help of the function "Calibrate
current magazine", x- and y-values must
be individually determined for each
magazine if the changer is not
completely
loaded.

174
9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx) Adjustment Instructions SIPLACE HS-50
9.6 Calibration Collect & Place Head Nozzle Changer Softwareversion SR.501.xx Edition 12/00
NOTE
The pick-up height must be determined for
each magazine.
&DOLEUDWLRQRIWKH&XUUHQW0DJD]LQH
Example: Nozzle changer for C&P Head 1, not completely loaded with all magazines.
6,7(67
Å Select "C&P Heads" ==> "C&P Head 1" ==>
"C&P Head nozzle changer" ==> "Magazine number..." ==> "Type in magazine number and
accept" ==> "Calibrate current magazine".Repeat these instructions with all magazines.
Å Proceed under section "Calibration of Pick-Up Height". (See section 9.6.3).

Adjustment Instructions SIPLACE HS-50 9 Calibration of SIPLACE HS-50 (incl. SITEST version 501.xx)
Softwareversion SR.501.xx Edition 12/00 9.6 Calibration Collect & Place Head Nozzle Changer
175
&DOLEUDWLRQRI3LFN8S+HLJKW
Å
Ascertain, that there is a nozzle on the lower segment, and that all garages selected below, are empty.
6,7(67
Å Select "Magazine number..." ==> "Type in magazine number and accept" ==> "Garage number..." ==>
"Type in garage number and accept" ==> "Calibrate pick-up height" ==> "OK".
Å Repeat this procedure for all magazines.
Å Select "Main View" ==> "Save machine data".
NOTE
Each individually determined pick-up
height (z-position) will be displayed in a di-
alogue box, after the calibration.
The z-position of the reject container will
be calculated from the pick-up height
determined for the last magazine.
If you want to test if the calibration was
successful, you should always FIRST
save the determined calibration data
("Main view" ==> "Settings" ==> "Save
machine data"). After saving the data,
return to the display "C&P Head nozzle
changer".
With the help of the functions "Place / Pick-
up" you can test the calibration result.