Adjus t ment In str uc tio ns SI PLA CE HS- 50 2 Operational Safety Edition 12/00 2.2 Safety Equipm ent 33 67 $57%XWWRQ:KLWH,WHPL Q ILJ  After sw itchi ng on th e main sw itch, you wi ll be pr ompted t …

100%1 / 186
2 Operational Safety Adjustment Instructions SIPLACE HS-50
2.2 Safety Equipment Edition 12/00
32
 )XQFWLRQV
0DLQ6ZLWFKLQ2))3RVLWLRQ6HHLWHPLQILJ
The main switch disconnects the three phases L1, L2 and L3 from the power supply.
DANGER
The following components still carry potentially lethal voltages even if the main switch is switched
off:
Cable connection terminals 1, 3 and 5 of S1 main switch
Z1 main power filter
BU1 service socket
F1 automatic circuit breaker for the service socket
The uninterruptable power supply and the station computer may also still carry potentially
lethal voltages when the main switch is switched off.
Incorrect handling of the placement system can therefore result in death or severe injury or
considerable damage to equipment.
NOTE
The color of all individual wires, which still carry potentially lethal voltages even if the main switch
is switched off, is brown.
Å Always follow the applicable accident prevention and DIN regulations (especially DIN EN 60
204, part 1) and the specific regulations of your country.
Å The safety doors to the power supply unit must be opened by appropriately qualified and
trained personnel only.
0DLQ6ZLWFKLQ213RVLWLRQ
Switching on of the main switch, will start the station computer and machine controller.
All supply voltages, apart from the link voltages for the gantry axes (200 V) and star axes (100 V),
are then available.
(0(5*(1&<6723%XWWRQ%ODFN,WHPLQILJ
With the help of these buttons you can turn off the placement system.
Adjustment Instructions SIPLACE HS-50 2 Operational Safety
Edition 12/00 2.2 Safety Equipment
33
67$57%XWWRQ:KLWH,WHPLQILJ
After switching on the main switch, you will be prompted to press the START button in order to
start the placement system for placement orders. The same prompt will appear if you opened the
protective covers or pressed the EMERGENCY STOP button.
&RPSRQHQW&RXQWHU,WHPLQILJ
Here you can check the number of the placed components
6HUYLFH6RFNHW,WHP LQILJ
The service socket is contained in the power supply unit and is protected by the safety doors. It
can only be used if the placement system is connected to the main power supply via a 5-wire
connection (L1, L2, L3, MP and PE). The socket cannot be used with a 4-wire connection, e.g.
without N.
Always follow the safety instructions concerning potentially lethal voltages - even when the place-
ment system is switched off.
(0(5*(1&<6723%XWWRQODWFKHGZLWK2YHUULGH3URWHFWLRQ$FFRUGLQJWR(1
,WHPLQILJILJ
The EMERGENCY STOP button is red and shaped like a mushroom. Activated, it remains latched
in its ON position. If you press the EMERGENCY STOP button, the switching contact of the safety
circuit will open and the protective contactor combination (PCC) will trip. The link voltage (200 V)
for the gantry axes is switched off, whereas the link voltage (100 V) for the star axes is reduced to
6 VDC. The servo amplifiers for the dp - and z-axes are still supplied with 30 VDC. The signalling
contact of the EMERGENCY STOP buttons closes and the message "EMERGENCY STOP acti-
vated" appears on screen. The following modules:
PCB conveyor
PCB clamping
width adjustment
PCB stopper and
used tape cutter
become deactivated.
NOTE
Placement will be interrupted and once the machine is back to functioning mode, may either be
continued or cancelled.
2 Operational Safety Adjustment Instructions SIPLACE HS-50
2.2 Safety Equipment Edition 12/00
34
3URWHFWLYH&RYHU6ZLWFKHV,WHP LQILJ
DQG&RYHU6ZLWFKHV,WHP LQILJ
Å With the help of these switches you may check whether the protective covers and other covers
are closed.
If the covers are closed, the safety contact is closed and the signalling contact is open. If you
open one of the covers, the safety circuit opens and the signalling circuit closes. The individual
components will either be activated or deactivated, depending on the position of the key switch
(Item 5).
3URWHFWLYHFRQWDFWRUFRPELQDWLRQ7.,WHP LQILJ
The protective contactor combination is contained in the power supply unit. It will not be activated
or deactivated if any safety - related functions should fail.
.H\6ZLWFKLQ3RVLWLRQ,WHPLQILJ
NOTE
For normal mode the key switch remains open, i.e. in position "0".
The key has been drawn.
The protective contactor combination (PCC) trips if one of the protective covers is opened. The
link voltage (200 V) of the gantry axes will be switched off and the link voltage of the star axes
(100 V) will be reduced to 6 VDC. All modules are deactivated.
.H\6ZLWFKLQ3RVLWLRQ,
WARNING
The protective covers must only be opened by appropriately qualified and trained personnel and
only when the key switch is closed (position "I").
The protective contactor combination (PCC) trips as soon as one of the protective covers is
opened. The link voltage of the gantries gets switched off and the link voltage of the star - axes
will be reduced to 6 VDC. The star of the placement head can be cycled at a lower speed if the
cover is open. The following modules:
PCB clamping,
PCB stopper,
lifting table motors and
tape cutting units
become deactivated.