DEK INFINITY USER MANUAL.pdf.pdf - 第176页

INFINITY ',$*126 7,&6 6<67(0 5.8 User Manual Software Version 7 The menu bar changes to the following: Exit returns operation to the system diagnostics page. T oggle Beacon Selecting any one of the three togg…

100%1 / 356
INFINITY
',$*1267,&6
6<67(0
Software Version 7 User Manual 5.7
MMOV3 Group 1
(X11)
MMOV3 Group 2
(X11)
MMOV3 Group 3
(X11)
Display All
Analogue Inputs
Selecting this diagnostic function opens the following window:
MMOV 3 Group 1
Point Description
---------------------
---------
-------
-----------
------
Bit No
Sense
Direction
State
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
0
1
2
3
4
5
6
7
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Input
Input
Input
Input
Input
Input
Input
Input
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
IN 8
IN 9
IN A
IN B
IN C
IN D
IN E
IN F
Signal
MMOV 3 Group 2
Point Description
---------------------
---------
-------
-----------
------
Bit No
Sense
Direction
State
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
0
1
2
3
4
5
6
7
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Output
Output
Output
Output
Output
Output
Output
Output
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
Totem 0
Totem 1
Totem 2
Totem 3
Totem 4
Totem 5
Totem 6
Totem 7
Signal
MMOV 3 Group 3
Point Description
---------------------
---------
-------
-----------
------
Bit No
Sense
Direction
State
Not Used
Not Used
Not Used
Coupling Left
Coupling Right
Screen Coupling
Head Lift Direction
Head Lift Enable
0
1
2
3
4
5
6
7
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Positive
Output
Output
Output
Output
Output
Output
Output
Output
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
Source 0
Source 1
Source 2
Source 3
Source 4
Source 5
Source 6
Source 7
Signal
Analogue I/O Values
Description
--------------
----------------
Integer Value
--------------------
Converted Value
Pressure Sensor
Temperature
Relative Humidity
2327
3644
2985
8.51 kg
24.573 C
42.386 %
o
INFINITY
',$*1267,&6
6<67(0
5.8 User Manual Software Version 7
The menu bar changes to the following:
Exit returns operation to the system diagnostics page.
Toggle Beacon Selecting any one of the three toggle beacon diagnostic functions, alternately
switches them between on and off.
Toggle Lid Bolt Selecting this function alternately extends and retracts the lid bolt.
Data Logging Selecting this diagnostic function alternately enables and disables data logging
during diagnostic operations.
Change Edit
Password
Selection of this option prompts the user to enter a new password.
Change
Diagnostics
Password
Selecting this diagnostic function either allows a password to be entered or
changes an existing password. This password protection inhibits unauthorized
entry into diagnostics.
Change Terminate
Password
Selecting this diagnostic function either allows a password to be entered or
changes an existing password. This password protection inhibits unauthorized
operation of the terminate control program.
Change Adjust
Password
Selecting this diagnostic function allows a password to be entered or changes an
existing password. This password protection inhibits unauthorized adjustments.
Change Fiducial
Set-up Password
Selecting this diagnostic function allows a password to be entered or changes an
existing password. This password protection inhibits unauthorized entry into the
fiducial setup.
Change
Maintenance
Password
Selecting this diagnostic function allows a password to be entered or changes an
existing password. This password protection inhibits unauthorized entry into the
maintenance functions.
Terminate Control
Program
Selecting this diagnostic function terminates the Infinity control program and
returns to Windows NT.
Exit
INFINITY
',$*1267,&6
35,17+($'
Software Version 7 User Manual 5.9
PRINT HEAD Selecting this diagnostics module opens the following window:
The menu bar changes displaying the following:
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight bar.
Exit returns operation to the module diagnostics page.
Raise Head Under
2 Button Control
Selecting this diagnostic function allows the print head to be raised using the two
button control. These switches must be operated simultaneously.
Lower Head Under
2 Button Control
Selecting this diagnostic function allows the print head to be lowered using the
two button control. These switches must be operated simultaneously.
Toggle Head Latch Selecting this diagnostic function alternately switches the print head magnetic
latches on and off.
Toggle Lid Bolt Selecting this diagnostic function alternately extends and retracts the lid bolt.
Head Up Sensor This diagnostic function continuously displays the status of the head up sensor.
Head Down Sensor This diagnostic function continuously displays the status of the head down
sensor.
Lid Bolt Shut This diagnostic function continuously displays the status of the printhead lid bolt
sensor.
Head Prop Stowed This diagnostic function continuously displays the status of the head prop
stowed sensor.
Left Jog Button This diagnostic function continuously displays the status of the left jog button.
Right Jog Button This diagnostic function continuously displays the status of the right jog button.
Head Diagnostics
ON
Head Up Sensor
Head Down Sensor
Lid Bolt Shut
Head Prop Stowed
Left Jog Button
Right Jog Button
ON
Raise Head Under 2 Button Control
Lower Head Under 2 Button Control
Toggle Head Latch
Toggle Lid Bolt
ON
ON
ON
ON
ON
ON
Run
Diagnost
Next Previous Exit