DEK INFINITY USER MANUAL.pdf.pdf - 第92页

INFINITY 0$&+,1( 352*5$ 00,1* 0(183$5$ 0(7(5 6 1.90 User Manual Software Versi on 7 Mesh Front This parameter sets the distance between the inner edge of the screen frame and the screen glue line at the front of th…

100%1 / 356
INFINITY
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 7 User Manual 1.89
MENU PARAMETERS
Each product has a set of parameters which are unique to that particular product
and which need to be setup to obtain acceptable printing results. These parame-
ters are listed below with a definition of each as an aid to machine setup.
Product Name The file name for the particular product. The name can consist of up to eight
alphanumeric characters with no punctuation.
Product ID The product ID is a parameter that allows a description of the product. This
string may be up to 32 characters long, but only the first 20 characters are
displayed.
Product Barcode The barcode number for the particular product. The barcode can be up to twenty
characters long. This parameter is only used if the machine if fitted with a
product barcode reader.
Screen Barcode The barcode number that identifies the particular screen to be used with this
particular product. The barcode can be up to twenty characters long. If the screen
has a barcode printed on it in the correct place and the machine is initialized to
read the code, the screen is checked to ensure it is correct after it has been fitted.
If it is incorrect a message is displayed on the monitor. This parameter is only
used if the machine is fitted with a product barcode reader.
Dwell Height The parameter allows the user to set the squeegee dwell height. Setting of a
lower height helps the media to stay evenly spread across the length of the
squeegee when a less viscous media is used. Setting a high height allows
viewing of the paste roll.
Dwell Speed This preference adjusts the speed at which the squeegee moves to dwell height.
A slower speed helps to reduce the spreading of a less viscous media, ie flux. It
should be noted that decreasing this speed causes the cycle time to increase.
Image Detail This parameter allows the user to modify the screen image data of the selected
screen library file. Once selected, pressing Incr. or Decr. Keys opens the Image
Detail Configuration page.
NOTE
This parameter is only displayed, if Screen Size in Set Preferences has been
selected to Screen Library.
Minimum Maximum Increment Default
5.0mm 40.0mm 1.0mm 30.0mm
Minimum Maximum Increment Default
10.0mm/sec 30.0mm/sec 1.0mm/sec 24.0mm/sec
INFINITY
0$&+,1(352*5$00,1*
0(183$5$0(7(56
1.90 User Manual Software Version 7
Mesh Front This parameter sets the distance between the inner edge of the screen frame and
the screen glue line at the front of the frame. It defines the area that should not
be contacted by the squeegees/ProFlow.
Mesh Rear This parameter sets the distance between the inner edge of the screen frame and
the screen glue line at the rear of the frame. It defines the area that should not be
contacted by the squeegees/ProFlow.
Mesh Left This parameter sets the distance between the inner edge of the screen frame and
the screen glue line at the left of the frame. It defines the area that should not be
contacted by the squeegees/ProFlow.
Mesh Right This parameter sets the distance between the inner edge of the screen frame and
the screen glue line at the right of the frame. It defines the area that should not
be contacted by the squeegees/ProFlow.
Image X This parameter defines the dimension in the X axis from the right inner edge of
the screen frame to either:
Right hand edge of the image - right justified image
Left hand edge of the image - left justified image
Centre line of the image - centre justified image
Image Y This parameter defines the dimension in the Y axis from the front inner edge of
the screen frame to either:
Front edge of the image - front justified image
Rear edge of the image - rear justified image
Centre line of the image - centre justified image
Minimum Maximum Increment Default
0.0mm Screen Length - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
0.0mm Screen Length - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
0.0mm Screen Width - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
0.0mm Screen Width - 250.0mm 0.1mm 38.0mm
Minimum Maximum Increment Default
60.0mm Screen Length - 100.0mm 0.1mm 330.4mm
Minimum Maximum Increment Default
60.0mm Screen Width - 100.0mm 0.1mm 330.4mm
INFINITY
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 7 User Manual 1.91
Image X
Justification
This parameter defines the position of the image about the Image X parameter.
The image can be left, right or centre justified about Image X. Options are:
Image Y
Justification
This parameter defines the position of the image about the Image Y parameter.
The image can be front, rear or centre justified about Image Y. Options are:
Barcode Y This parameter defines the dimension between the centre of the barcode to the
outer rear edge of the screen frame or adaptor.
Screen Adapter The type of screen adapter needed, if any, for the screen to be used for this
product.
NOTE
This parameter is not displayed, if Screen Size in Set Preferences has been
selected to Screen Library.
Screen Image The position of the image in the screen frame. Options are:
NOTE
This parameter is not displayed, if Screen Size in Set Preferences has been
selected to Screen Library.
Option Default
Left Centre
Right
Centre
Option Default
Front Centre
Rear
Centre
Minimum Maximum Increment Default
10.0mm Screen Length - 10.0mm 0.1mm 97.0mm
Options Available
None
255
Sanyo
Heraeus
20 X 20
12 X 12
Options Available Notes
Edge Justified Permitted for Sanyo and Fuji frames only
Centre Justified -