1.3.4.3
1.3.4.3 Handling ESD Modules
Handling ESD Modules
Do not touch electronic modules unless it is absolutely essential to do so in order to carry out other work.
If it is necessary, make sure that you do not touch the pins or printed conductors when you pick up flat
modules.
Do not touch components unless
▪ You are constantly earthed by an ESD wrist strap or
▪ You are wearing ESD shoes or ESD shoe earthing strips on an ESD floor.
Always discharge yourself before you touch an electronic module. To do this, simply touch a conductive
and earthed object immediately before you touch the module (such as unpainted parts of a switch cab-
inet, a water pipe, etc.).
Do not allow modules with chargeable and highly insulating materials to touch one another, e.g. plastic
films, insulating table surfaces or items of clothing made from synthetic fibers.
Always place the modules on a conductive surface (table with an ESD coating, conductive ESD foam,
ESD bag or container).
Do not bring modules near visual display units, monitors or televisions. Keep them at least 10 cm away
from the screen.
1.3.4.4
1.3.4.4 Measurements and Modifications to ESD Modules
Measurements and Modifications to ESD Modules
Measurements of the assemblies may only be taken if
▪ The measuring device has been grounded (e.g. via protective conductor) or
▪ The measuring head of the potential-free measuring device has been briefly discharged before
measurement (e.g. touching blank metal control unit housing).
► Always use an earthed soldering iron if you carry out any soldering work.
1.3.4.5
1.3.4.5 Dispatching ESD Modules
Dispatching ESD Modules
► Always store modules and components in conductive packaging (e.g. metallized plastic bags or met-
al sleeves) and dispatch them in conductive packaging.
► If the packaging is not conductive, place the modules in a conductive envelope before packaging.
Use conductive foam rubber, ESD bags, domestic aluminum foil or paper, for example. NEVER use
plastic bags or film.
► If the module has integral batteries, ensure that the conductive packaging does not touch or short-
circuit the battery terminals and, if necessary, first cover the terminals with insulating tape or mate-
rial.
1.3.5
1.3.5 Release History
Release History
1.4
1.4 Staff Qualifications and Training
Staff Qualifications and Training
Qualified or adequately trained personnel means that these people are familiar with the setting up, op-
eration and maintenance of automatic placement systems and add-on devices and are suitably qualified,
e.g.:
▪ Have been trained, instructed or authorized to switch on and off, isolate, earth and identify electrical
circuits and system components in accordance with normal safety standards.
▪ Have been trained or instructed in the upkeep and use of appropriate safety equipment in accord-
ance with normal safety standards.
▪ Have received first aid training.
Edition Changes
07/2016 First edition
Introduction
Staff Qualifications and Training 1.3.5 Release History
52 Gantry Exchange Portaltausch

Brief Description
2.1.1 Gantries Overview of the Modules
Gantry Exchange Portaltausch 53
2
2 Brief Description
Brief Description
This section gives an overview of the gantry and the scope of delivery.
2.1
2.1 Overview of the Modules
Overview of the Modules
2.1.1
2.1.1 Gantries
Gantries
2.2
2.2 Prerequisites
Prerequisites
Gantries can be replaced in all X-Series S machines.
2.3
2.3 Scope of Delivery
Scope of Delivery
▪ Select the relevant gantry:
▪ Gantry system assy SX4a [03092146Sxx]
▪ Gantry system assy, rotated SX4a [03092433Sxx]
▪ Tape measure X-Series S [03092558S-xx]
▪ Tape measure micron: [03101458-xx]
▪ Gantry labeling 1,2,3,4 [03009553-xx]
▪ Label set, warning labels for China SX4/DX4, X-Series S [03091189-xx]
▪ Depending on the heads installed, you may need:
Pneumatic blanking plug (various sizes available) for the vacuum distributor:
▪ Blanking plug QSC-4H [00330249-01]
▪ Blanking plug QSC-6H [00337891-01]
▪ Blanking plug QSC-8H [03010908-01]
▪ Blanking plug QSC-12H [03015210-01]
▪ Assembly instructions "Gantry Replacement SIPLACE X-Series S" [00197461-xx]
1. Head interface and Vision board
The Vision board is fitted onto the head interface.
2. Gantry trailing cables split for Y axis
3. Y-Axis
4. X axis
5. Gantry trailing cables split for X axis
6. Y drive (primary)
7. Y axis scale
Machine Gantry 1 Gantry 2 Gantry 3 Gantry 4
X2 S 03092146Sxx No 03092146Sxx no
X3 S 03092146Sxx 03092146Sxx 03092146Sxx no
X4 S, X4 S micron 03092146Sxx 03092146Sxx 03092146Sxx 03092146Sxx
X4i S, X4i S micron 03092146Sxx 03092433Sxx 03092146Sxx 03092433Sxx