00197461-01_AI_Portaltausch_X-Serie_S_INTERN_de_en.pdf - 第68页

Installation Final work 68 Gantry Exchange Portaltausch ► Perform PCB mapping.

100%1 / 76
Installation
Final work
Gantry Exchange Portaltausch 67
Fitting the side cover
Fit the side cover.
Warning label, if needed
Attach the warning labels to the new gantry. Clean the adhesive surfaces first with ethanol or isopro-
panol (IPA).
3.5
3.5 Final work
Final work
Switch on the machine
Move the component trolley into the machine.
Perform a complete calibration.
If a TwinHead is installed, you will need to calibrate
the height of the TwinHead. Select "Calibrate Z ax-
es".
Installation
Final work
68 Gantry Exchange Portaltausch
Perform PCB mapping.
Appendix
4.1.1 Gantry interface Description of Boards
Gantry Exchange Portaltausch 69
4
4 Appendix
Appendix
4.1
4.1 Description of Boards
Description of Boards
4.1.1
4.1.1 Gantry interface
Gantry interface
Gantry interface [03089220-03]:
This gantry interface is used for gantries 1 and 3.
X3) Y axis motor power
X4) Y axis motor temperature sensor
X6) Y axis incremental encoder
Gantry interface [03089221-03]:
This gantry interface is used for gantries 2 and 4.
X3) Y axis motor power
X4) Y axis motor temperature sensor
X6) Y axis incremental encoder