00197461-01_AI_Portaltausch_X-Serie_S_INTERN_de_en.pdf - 第68页
Installation Final work 68 Gantry Exchange Portaltausch ► Perform PCB mapping.

Installation
Final work
Gantry Exchange Portaltausch 67
Fitting the side cover
► Fit the side cover.
Warning label, if needed
► Attach the warning labels to the new gantry. Clean the adhesive surfaces first with ethanol or isopro-
panol (IPA).
3.5
3.5 Final work
Final work
► Switch on the machine
► Move the component trolley into the machine.
► Perform a complete calibration.
► If a TwinHead is installed, you will need to calibrate
the height of the TwinHead. Select "Calibrate Z ax-
es".

Installation
Final work
68 Gantry Exchange Portaltausch
► Perform PCB mapping.

Appendix
4.1.1 Gantry interface Description of Boards
Gantry Exchange Portaltausch 69
4
4 Appendix
Appendix
4.1
4.1 Description of Boards
Description of Boards
4.1.1
4.1.1 Gantry interface
Gantry interface
Gantry interface [03089220-03]:
This gantry interface is used for gantries 1 and 3.
X3) Y axis motor power
X4) Y axis motor temperature sensor
X6) Y axis incremental encoder
Gantry interface [03089221-03]:
This gantry interface is used for gantries 2 and 4.
X3) Y axis motor power
X4) Y axis motor temperature sensor
X6) Y axis incremental encoder