4OM-1505-004_w.pdf - 第146页

4OM-1505 2-31 2. T roubleshooting on Each Section : Chap.2 (10 Table Chute Width) T4B28 Error ID Error Name, Description, Cause, and Remedy 1001000 T able Chute Width Origin Zeroing opn. was incompleted, within specied …

100%1 / 181
4OM-1505
2-30
2. Troubleshooting on Each Section : Chap.2
0906-001
Error ID Error Name, Description, Cause, and Remedy
0905000 PCB Backup Axis Driver
Driver alarm signal was detected.
0908000 PCB Backup Axis Driver
Driver Over-Heat
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If this operation does not reset the
machine to its normal condition, contact our service personnel for details.
0911000 PCB Backup
Axis Timing
Task has not been completed unable to continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
0912000 PCB Backup
Axis Data
The data was detected outside of the possible range.
(Cause 1) The specied data may have exceeded the movable range.
(Remedy 1) Check the parameter in the "PCB Chuck Height" text box ("OFFSET DATA"
window).
0913000
PCB Backup Axis Origin
Zeroing Opn. Not Complete.
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.
T4B27
4OM-1505
2-31
2. Troubleshooting on Each Section : Chap.2
(10 Table Chute Width)
T4B28
Error ID Error Name, Description, Cause, and Remedy
1001000 Table Chute Width Origin
Zeroing opn. was incompleted, within specied time.
(Cause 1) Dirt adheres to the sensor and the optical beam is shielded.
(Cause 2) The sensor (B251) is defective.
(Cause 3) The
driver is malfunctioning or an error has occurred during communication with
the host CPU.
(Remedy 1) Wipe off dirt on the sensor and zero the table chute width axis again.
(Remedy 2) It is required to replace the sensor with a new one. Contact our service
personnel for details.
(Remedy 3) Shut down the power of the machine once and power up the machine again.
After that, zero the table chute width axis. If this operation does not reset
the machine to its normal condition, the driver may be defective. Contact our
service personnel for details.
1002000
Table Chute Width Origin
Detect lost pulse error.
(Cause 1) The motor is overloaded and has a loss of synchronism.
(Remedy 1) Check for any obstacle around the PEC recognition X axis and perform the
zeroing operation. If this operation does not reset the machine to its normal
condition, contact our service personnel for details.
1008000 Table Chute Width Driver
Driver Over-Heat
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If this operation does not reset the
machine to its normal condition, contact our service personnel for details.
1012000 Table Chute Width Interlock
PCB Backup
Axis is not at origin.
(Cause 1) The PCB backup axis origin sensor (B231) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The table chute width axis was activated after the PCB backup axis had moved
up. (during the manual operation)
(Remedy 1) Check how the sensor is working in "DEVICE CHECK" window.
When the sensor is not working, it is required to replace the sensor with a
new one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 3) Perform the zeroing operation and restart the operation.
1013000
Table Chute Width Interlock
PCB warpage protection was down.
(Cause 1) The table chute width axis was activated after the PCB warpage top holder had
moved down.
(Remedy 1) Move up the PCB warpage top holder and restart the operation.
0906-001
4OM-1505
2-32
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B29
Error ID Error Name, Description, Cause, and Remedy
1014000 Table Chute Width Interlock
PCB stopper was down.
(Cause 1) The table chute width axis was activated after the PCB stopper had moved
down.
(Cause 2) The PCB stopper upper limit sensor (B70) is defective.
(Remedy 1) Move up the PCB stopper and restart the operation.
(Remedy 2) Check how the sensor is working in "DEVICE CHECK" window. If this
operation does not reset the machine to its normal condition, it is required to
replace the sensor with a new one. Contact our service personnel for details.
1015000 T
able Chute Width Interlock
Table-Z Axis is not at origin.
(Cause 1) The table Z axis origin sensor (B171) is defective.
(Cause 2) The operation timing is shifted from the normal one.
(Cause 3) The table chute width axis was activated after the table Z axis had moved up.
(during the manual operation)
(Remedy 1) Check how the sensor is working in "DEVICE CHECK" window.
When the sensor is not working, it is required to replace the sensor with a
new one. Contact our service personnel for details.
(Remedy 2) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 3)
Perform the zeroing operation and restart the operation.
1016000 Table Chute Width Interlock
Detected interference to backuppin or JIG.
(Cause 1) A wrong jig is attached or a backup pin is attached to a wrong position.
(Cause 2) A wrong parameter is set in the "Y" text box of "PCB Size [mm]" in the "Pattern
Program" window.
(Cause 3) The width error detection sensor (B49) is defective.
(Remedy 1) Check the location of the jig or the backup pins and restart the operation.
(Remedy 2)
Check the contents of the pattern program and restart the operation.
(Remedy 3) Check how the sensor is working in "DEVICE CHECK" window.
When the same error occurs after the restart operation, it is required to
replace the sensor with a new one. Contact our service personnel for details.
1018000 Table Chute Width Data
The data was detected outside of the possible range.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and restart the operation. If the machine is not reset to its
normal condition, shut down the power of the machine once and power up
the machine again. After that, restart the operation. When the same error still
occurs, contact our service personnel for details.
1019000 T
able Chute Width Origin
Zeroing Opn. Not Complete.
(Cause 1) The motor axis was activated before the zeroing operation was completed.
(Remedy 1) Perform the zeroing operation.