4OM-1505-004_w.pdf - 第69页

4OM-1505 1-18 3. Maintenance Spots : Chap.1 3.2 Inspection, Cleaning, and Lubrication Spots The following describes about the maintenance tasks required for each individual units. Reference Refer to "2. Maintenance …

100%1 / 181
4OM-1505
1-17
3. Maintenance Spots : Chap.1
3. Maintenance Spots
3.1 Whole View
Notice
Any operations with a cover(s) being removed are included.
After the maintenance work, be sure to attach the cover.
PEC Recognition Section
Air Source
Stencil Holder Section
Stencil Recognition Section
Cleaning Section
Blower Unit
L Conveyor Section
R Conveyor Section
Table Section
Squeegee Head Section
F4A3
Reference
Refer to "3.2" and the subsequent items for the detailed information on the spots
of each section to be maintained and how to maintain them.
1002-002
4OM-1505
1-18
3. Maintenance Spots : Chap.1
3.2 Inspection, Cleaning, and Lubrication Spots
The following describes about the maintenance tasks required for each individual
units.
Reference
Refer to "2. Maintenance Check List" for the maintenance items classied based
on frequency.
3.2.1 Air Source
Drain
Follow the steps below to purge the drain.
(1) Put a container under the drain outlet.
(2) Press the orange button.
Every Week Cleaning
Drain Button
F4A4
0906-001
4OM-1505
1-19
3. Maintenance Spots : Chap.1
3.2.2 Squeegee Head Section
Squeegee
Every Day Cleaning
Clean the squeegees with a rag soaked
in industrial alcohol (solvent) or
directly with industrial alcohol
(solvent).
Remove deteriorated solder paste.
Front Side
F4A5
Stencil Recognition Lighting
Glass Surface
Every Month Cleaning
Remove dirt and dust, etc.,
with an air blow brush for camera.
Rear Side
Lens
Camera
Lighting
F4A6
0906-001