4OM-1505-004_w.pdf - 第82页
4OM-1505 1-31 3. Maintenance Spots : Chap.1 Linear Guide for Chute W idth Adjustment (Right Side) Every 5 years Lubrication Linear Guide for Chute W idth Adjustment (Left Side) Every 5 years Lubrication Linear Guide for …

4OM-1505
1-30
3. Maintenance Spots : Chap.1
Every 6 Months Lubrication
Backup Table Vertical-Axis
Guide Bushing (Three)
Backup Table Vertical-Axis
Ball Screw (Four)
Every 6 Months Lubrication
Backup Table Vertical-Axis
Guide Bushing
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Note
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
F4A19
Linear Guide for PCB Clamping
Every Month Cleaning
Detach the cover and clean
the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Linear Guide for PCB Clamping
Every 5 years Lubrication
Detach the cover and apply grease
with a brush or a spatula.
Rear Side
Note
F4A20
0906-001

4OM-1505
1-31
3. Maintenance Spots : Chap.1
Linear Guide for Chute Width
Adjustment (Right Side)
Every 5 years Lubrication
Linear Guide for Chute Width
Adjustment (Left Side)
Every 5 years Lubrication
Linear Guide for Chute Width
Adjustment (Right Side)
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Linear Guide for Chute Width
Adjustment (Left Side)
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Right Side
Left Side
Note
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
Torapezoid Screw for Chute Width
Change
(Left Side), (Right Side)
Every 6 Months Lubrication
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
Note
F4A21
0906-001

4OM-1505
1-32
3. Maintenance Spots : Chap.1
3.2.7 Table Section
Table X-Axis Ball Screw
Move the table Z axis up to
the printing position.
Detach the cover located in
front of the table.
Apply grease to the X-axis
ball screw with a brush or a
spatula.
Every 6 Months Lubrication
(1)
(2)
(3)
F4A23
0906-001